A TELEMETRY-INSTRUMENTATION SYSTEM FOR MONITORING MULTIPLE SUBCUTANEOUSLY IMPLANTED GLUCOSE SENSORS

被引:71
作者
SHULTS, MC
RHODES, RK
UPDIKE, SJ
GILLIGAN, BJ
REINING, WN
机构
[1] MARKWELL MED INST,MADISON,WI 53713
[2] REINING INT INC,MADISON,WI 53711
[3] MARKWELL MED INST,R&D,RACINE,WI
基金
美国国家卫生研究院;
关键词
D O I
10.1109/10.324525
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
An implantable potentiostat-radiotelemetry system for in vivo sensing of glucose is described. An enzyme electrode sensor measures the oxidation current of hydrogen peroxide formed by the stoichiometric conversion of glucose substrate and oxygen cofactor in an immobilized glucose oxidase layer. The sensor current is converted to a frequency and transmitted at programmable intervals (4, 32, 256 s) to a remote receiver. Low power CMOS circuitry is employed and device operation for up to 1.5 years is predicted using two series connected 250 mAh lithium cells. Crystal controlled RF frequencies uniquely identify each sensor allowing over 10 sensors within the same 10 m radius. A custom interface card allows a PC to program the receiver and handle the transmitted sensor data using software written in Microsoft C and QuickBasic. Software control allows on-the-fly sensor addition or subtraction to the sensor group being monitored. Over 10 sensors can be tracked long-term using the longest transmit interval, or four sensors can be tracked during short-term infusion studies when the transmit interval is reduced to 4 s. The design, construction, operation, and performance of the system hardware and software are described and evaluated.
引用
收藏
页码:937 / 942
页数:6
相关论文
共 9 条
[1]   APPLICATION OF CHRONIC INTRAVASCULAR BLOOD-GLUCOSE SENSOR IN DOGS [J].
ARMOUR, JC ;
LUCISANO, JY ;
MCKEAN, BD ;
GOUGH, DA .
DIABETES, 1990, 39 (12) :1519-1526
[2]   EVALUATION OF A SUBCUTANEOUS GLUCOSE SENSOR OUT TO 3 MONTHS IN A DOG-MODEL [J].
GILLIGAN, BJ ;
SHULTS, MC ;
RHODES, RK ;
UPDIKE, SJ .
DIABETES CARE, 1994, 17 (08) :882-887
[3]   A TELEMETRY-INSTRUMENTATION SYSTEM FOR CHRONICALLY IMPLANTED GLUCOSE AND OXYGEN SENSORS [J].
MCKEAN, BD ;
GOUGH, DA .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1988, 35 (07) :526-532
[4]   TELEMETRY GLUCOSE MONITORING DEVICE WITH NEEDLE-TYPE GLUCOSE SENSOR - A USEFUL TOOL FOR BLOOD-GLUCOSE MONITORING IN DIABETIC INDIVIDUALS [J].
SHICHIRI, M ;
ASAKAWA, N ;
YAMASAKI, Y ;
KAWAMORI, R ;
ABE, H .
DIABETES CARE, 1986, 9 (03) :298-301
[5]  
SHICHIRI M, 1982, LANCET, V2, P1129
[6]   Enzymatic glucose sensors: Improved long-term performance in vitro and in vivo [J].
Updike, S.J. ;
Shults, M.C. ;
Rhodes, R.K. ;
Gilligan, B.J. ;
Luebow, J.O. ;
Von Heimburg, D. .
ASAIO Journal, 1994, 40 (02) :157-163
[7]   LABORATORY EVALUATION OF NEW REUSABLE BLOOD-GLUCOSE SENSOR [J].
UPDIKE, SJ ;
SHULTS, MC ;
CAPELLI, CC ;
VONHEIMBURG, D ;
RHODES, RK ;
JOSEPHTIPTON, N ;
ANDERSON, B ;
KOCH, DD .
DIABETES CARE, 1988, 11 (10) :801-807
[8]   IMPLANTING THE GLUCOSE ENZYME ELECTRODE - PROBLEMS, PROGRESS, AND ALTERNATIVE SOLUTIONS [J].
UPDIKE, SJ ;
SHULTS, M ;
EKMAN, B .
DIABETES CARE, 1982, 5 (03) :207-212
[9]  
WILSON GS, 1992, CLIN CHEM, V38, P1613