摘要
A computer program is described for the optimization of reversed-phase multisolvent separations. After four initial gradient runs are carried out, calculation will locate a possible optimum with binary systems or select two binary mixtures with respect to both the analysis time and the selectivity. In this latter case, two additional experiments will locate the true optimum on a straight line joining these two binary compositions on the solvent triangle (ternary system). The efficiency of this procedure is demonstrated with an illustrative example.
引用
收藏
页码:559 / 565
页数:7
相关论文
共 11 条
[1]   PRACTICAL OPTIMIZATION OF THE SEPARATION OF A LIMITED SUBSET OF COMPONENTS BY USING ISOELUOTROPIC TERNARY ELUENT MIXTURES IN REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
BARTHA, A ;
BILLIET, HAH ;
DEGALAN, L .
JOURNAL OF CHROMATOGRAPHY, 1988, 458 :371-384
[2]  
BILLIET HAH, 1989, J CHROMATOGR, V485, P28
[3]   A CHEMOMETRIC INVESTIGATION OF THE SELECTIVITY OF MULTISOLVENT MOBILE PHASE SYSTEMS IN RP-HPLC [J].
COENEGRACHT, PMJ ;
METTING, HJ ;
SMILDE, AK ;
COENEGRACHTLAMERS, PJM .
CHROMATOGRAPHIA, 1989, 27 (3-4) :135-141
[4]   AN IMPROVED OPTIMIZATION PROCEDURE FOR THE SELECTION OF MIXED MOBILE PHASES IN REVERSED PHASE LIQUID-CHROMATOGRAPHY [J].
DROUEN, ACJH ;
BILLIET, HAH ;
SCHOENMAKERS, PJ ;
DEGALAN, L .
CHROMATOGRAPHIA, 1982, 16 :48-52
[5]  
HEINISCH S, 1990, ANALUSIS, V18, P83
[6]   COMPUTERIZED OPTIMIZATION OF THE MOBILE PHASE-COMPOSITION IN GRADIENT ELUTION REVERSED-PHASE HPLC [J].
HEINISCH, S ;
ROCCA, JL ;
KOLOSKY, M .
CHROMATOGRAPHIA, 1990, 29 (9-10) :482-488
[7]  
HEINISCH S, 1988, J CHEMOMETR, V3, P127
[8]   BAND-SPACING IN REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AS A FUNCTION OF SOLVENT STRENGTH - A SIMPLE AND FAST ALTERNATIVE TO SOLVENT OPTIMIZATION FOR METHOD DEVELOPMENT [J].
QUARRY, MA ;
GROB, RL ;
SNYDER, LR ;
DOLAN, JW ;
RIGNEY, MP .
JOURNAL OF CHROMATOGRAPHY, 1987, 384 :163-180
[9]   EFFECT OF MODEL INACCURACY ON SELECTIVITY OPTIMIZATION PROCEDURES IN REVERSED-PHASE LIQUID-CHROMATOGRAPHY [J].
SCHOENMAKERS, PJ ;
BLAFFERT, T .
JOURNAL OF CHROMATOGRAPHY, 1987, 384 :117-133
[10]   USE OF GRADIENT ELUTION FOR RAPID SELECTION OF ISOCRATIC CONDITIONS IN REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
SCHOENMAKERS, PJ ;
BILLIET, HAH ;
DEGALAN, L .
JOURNAL OF CHROMATOGRAPHY, 1981, 205 (01) :13-30