RESULTS OF INTRACORONARY STENTS FOR MANAGEMENT OF CORONARY DISSECTION AFTER BALLOON ANGIOPLASTY

被引:136
作者
HAUDE, M [1 ]
ERBEL, R [1 ]
STRAUB, U [1 ]
DIETZ, U [1 ]
SCHATZ, R [1 ]
MEYER, J [1 ]
机构
[1] ARIZONA HEART INST,PHOENIX,AZ
关键词
D O I
10.1016/0002-9149(91)90523-N
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Dissections after coronary balloon angioplasty are risk factors for acute or subacute vessel closures. Intracoronary stenting was developed to avoid these complications by pressing the intimal and medial flaps against the vessel wall, thus reducing the risk of acute thrombosis. A total of 22 stents were implanted into the coronary arteries of 15 patients with dissections after balloon angioplasty causing angina pectoris or ischemic electrocardiographic changes. Stent delivery was successful in all cases. In 1 patient acute stent thrombosis was documented and treated successfully by thrombolytic therapy. Another patient underwent coronary artery bypass surgery 24 hours later because of persisting angina. Angiograms after 24 hours documented vessel patency in the remaining 14 patients. Late control angiograms after 4 to 6 months were obtained in 12 of 14 patients. Vessel patency without significant restenosis was observed in 8 patients, restenosis in 3 and reocclusion in 1 patient. All 3 patients with multiple stent implantation had restenosis (n = 2) or reocclusion (n = 1), compared with 1 patient with single stent implantation. Thus, intracoronary stenting appears to be a secure and effective method of handling bailout situations caused by dissection after balloon angioplasty, with good long-term results when only a single stent is implanted.
引用
收藏
页码:691 / 696
页数:6
相关论文
共 23 条
  • [11] CORONARY DISSECTION - A PREDICTOR OF RESTENOSIS
    MATTHEWS, BJ
    EWELS, CJ
    KENT, KM
    [J]. AMERICAN HEART JOURNAL, 1988, 115 (03) : 547 - 554
  • [12] MEYER J, 1987, INTERNIST, V28, P736
  • [13] TREATMENT OF UNSTABLE ANGINA-PECTORIS WITH PERCUTANEOUS TRANS-LUMINAL CORONARY ANGIOPLASTY (PTCA)
    MEYER, J
    SCHMITZ, H
    ERBEL, R
    KIESSLICH, T
    BOCKERJOSEPHS, B
    KREBS, W
    BRAUN, PC
    BARDOS, P
    MINALE, C
    MESSMER, BJ
    EFFERT, S
    [J]. CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1981, 7 (04): : 361 - 371
  • [14] NORMAL AND STENOTIC RENAL-ARTERIES - EXPERIMENTAL BALLOON-EXPANDABLE INTRALUMINAL STENTING
    PALMAZ, JC
    KOPP, DT
    HAYASHI, H
    SCHATZ, RA
    HUNTER, G
    TIO, FO
    GARCIA, O
    ALVARADO, R
    REES, C
    THOMAS, SC
    [J]. RADIOLOGY, 1987, 164 (03) : 705 - 708
  • [15] ATHEROSCLEROTIC RABBIT AORTAS - EXPANDABLE INTRALUMINAL GRAFTING
    PALMAZ, JC
    WINDELER, SA
    GARCIA, F
    TIO, FO
    SIBBITT, RR
    REUTER, SR
    [J]. RADIOLOGY, 1986, 160 (03) : 723 - 726
  • [16] PALMAZ JC, 1986, SURGERY, V99, P199
  • [17] EARLY AND LATE ASSESSMENT OF STENOSIS GEOMETRY AFTER CORONARY ARTERIAL STENTING
    PUEL, J
    JUILLIERE, Y
    BERTRAND, ME
    RICKARDS, AF
    SIGWART, U
    SERRUYS, PW
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1988, 61 (08) : 546 - 553
  • [18] PRESENT-DAY COMPLICATION RATE OF PERCUTANEOUS TRANS-LUMINAL CORONARY ANGIOPLASTY IN STABLE AND UNSTABLE ANGINA
    RUPPRECHT, HJ
    ERBEL, R
    BRENNECKE, R
    POP, T
    JUNG, D
    KOTTMEYER, M
    HERING, R
    MEYER, J
    [J]. DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 1988, 113 (11) : 409 - 413
  • [19] A VIEW OF VASCULAR STENTS
    SCHATZ, RA
    [J]. CIRCULATION, 1989, 79 (02) : 445 - 457
  • [20] BALLOON-EXPANDABLE INTRACORONARY STENTS IN THE ADULT DOG
    SCHATZ, RA
    PALMAZ, JC
    TIO, FO
    GARCIA, F
    GARCIA, O
    REUTER, SR
    [J]. CIRCULATION, 1987, 76 (02) : 450 - 457