TEMPERATURE DISTRIBUTIONS DURING CLINICAL SCANNED, FOCUSED ULTRASOUND HYPERTHERMIA TREATMENTS

被引:41
作者
HYNYNEN, K
SHIMM, D
ANHALT, D
STEA, B
SYKES, H
CASSADY, JR
ROEMER, RB
机构
[1] UNIV ARIZONA, DEPT AEROSP & MECH ENGN, TUCSON, AZ 85724 USA
[2] ARIZONA CANC CTR, TUCSON, AZ 85724 USA
关键词
D O I
10.3109/02656739009140971
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
In this study a scanned focused ultrasound (SFUS) system was used to heat 66 tumours at various anatomical locations in 52 patients. A total of 160 treatments were given. On average, temperatures were measured in 14 or 15 locations in the scanned volume. The time-averaged temperatures over the 30 min treatment period in the best treatment of each tumour were 44.0 ± 2.4°C (mean ± SD) and 39.6 ± 1.5°C at the location of the highest and lowest sensor, respectively. On average, 39% of the sensors were above 42.5°C. When only the cases that were judged to be good candidates for the hyperthermia device were analysed, 64% of the sensors reached a temperature over 42.5°C with the highest temperature achieved being 45.9±2.3°C and the lowest 40.7 ± 1.4°C. Although the system tested has many technical limitations (for example, fixed frequency, beam geometry and power during the scan cycle), the results demonstrate that therapeutic temperatures can be achieved in many tumours. Significantly better temperatures are expected when all of the theoretical potential of scanned focused ultrasound systems has been used. © 1990 Informa UK Ltd All rights reserved: reproduction in whole or part not permitted.
引用
收藏
页码:891 / 908
页数:18
相关论文
共 25 条
  • [11] HYNYNEN K, 1990, IN PRESS INT J HYPER
  • [12] STANFORD-UNIVERSITY INSTITUTIONAL REPORT .1. EVALUATION OF EQUIPMENT FOR HYPERTHERMIA TREATMENT OF CANCER
    KAPP, DS
    FESSENDEN, P
    SAMULSKI, TV
    BAGSHAW, MA
    COX, RS
    LEE, ER
    LOHRBACH, AW
    MEYER, JL
    PRIONAS, SD
    [J]. INTERNATIONAL JOURNAL OF HYPERTHERMIA, 1988, 4 (01) : 75 - 115
  • [13] LELE PP, 1983, HYPERTHERMIA CANCER, P333
  • [14] LIN WL, 1990, IN PRESS MED PHYSICS
  • [15] MARMOR JB, 1979, CANCER-AM CANCER SOC, V43, P188, DOI 10.1002/1097-0142(197901)43:1<188::AID-CNCR2820430128>3.0.CO
  • [16] 2-7
  • [17] PREFOCAL PLANE HIGH-TEMPERATURE REGIONS INDUCED BY SCANNING FOCUSED ULTRASOUND BEAMS
    MOROS, EG
    ROEMER, RB
    HYNYNEN, K
    [J]. INTERNATIONAL JOURNAL OF HYPERTHERMIA, 1990, 6 (02) : 351 - 366
  • [18] SIMULATIONS OF SCANNED FOCUSED ULTRASOUND HYPERTHERMIA - THE EFFECTS OF SCANNING SPEED AND PATTERN ON THE TEMPERATURE-FLUCTUATIONS AT THE FOCAL DEPTH
    MOROS, EG
    ROEMER, RB
    HYNYNEN, K
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1988, 35 (05) : 552 - 560
  • [19] OVERGAARD J, 1987, INT J HYPERTHER, V3, P483, DOI 10.3109/02656738709140422
  • [20] QUALITY ASSURANCE PROBLEMS IN CLINICAL HYPERTHERMIA AND THEIR IMPACT ON THERAPEUTIC OUTCOME - A REPORT BY THE RADIATION-THERAPY-ONCOLOGY-GROUP
    PEREZ, CA
    GILLESPIE, B
    PAJAK, T
    HORNBACK, NB
    EMAMI, B
    RUBIN, P
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1989, 16 (03): : 551 - 558