ADVANTAGES OF HIGH-RESOLUTION AND HIGH-MASS RANGE MAGNETIC-SECTOR MASS-SPECTROMETRY FOR ELECTROSPRAY IONIZATION

被引:22
作者
CHAPMAN, JR
GALLAGHER, RT
BARTON, EC
CURTIS, JM
DERRICK, PJ
机构
[1] UNIV CAMBRIDGE,UNIV CHEM LABS,CAMBRIDGE,ENGLAND
[2] UNIV WARWICK,INST MASS SPECTROMETRY,COVENTRY CV4 7AL,W MIDLANDS,ENGLAND
[3] UNIV WARWICK,DEPT CHEM,COVENTRY CV4 7AL,W MIDLANDS,ENGLAND
来源
ORGANIC MASS SPECTROMETRY | 1992年 / 27卷 / 03期
关键词
D O I
10.1002/oms.1210270308
中图分类号
O62 [有机化学];
学科分类号
070303 ; 081704 ;
摘要
Electrospray ionization (ESI) mass spectra have been measured on a magnetic-sector double-focusing mass spectrometer for a number of proteins and peptides. It is pointed out how in theory raising the mass resolution of a mass spectrometer from 800-1000 to 2400-3000 significantly increases the precision with which the envelope of isotopic peaks of a protein ion (or other organic ion) can be defined, particularly at higher masses. Better definition of the isotopic envelope ought to lead to higher precision in the experimental determination of molecular mass, which has been demonstrated. It is shown how ESI mass spectra of high-mass molecules are significantly less congested at higher m/z values, so that for these molecules (RMM > 40 000) there is an advantage in being able to record peaks at higher m/z values (m/z > 2000) representing ions with fewer charges. Fragmentation of a small peptide in the ESI source has been found to provide sequence information.
引用
收藏
页码:195 / 203
页数:9
相关论文
共 15 条
[1]  
ALEXANDROV ML, 1984, DOKL AKAD NAUK SSSR+, V277, P379
[2]  
ALEXANDROV ML, 1985, ZHUR ANAL KHIM, V40, P1570
[3]   CORRECTION OF METASTABLE PEAK SHAPES TO ALLOW FOR INSTRUMENTAL BROADENING AND TRANSLATIONAL ENERGY SPREAD OF PARENT ION [J].
BALDWIN, MA ;
DERRICK, PJ ;
MORGAN, RP .
ORGANIC MASS SPECTROMETRY, 1976, 11 (04) :440-442
[4]  
BATEMAN RH, 1991, 39TH ASMS C MASS SPE
[5]  
CHAPMAN JD, IN PRESS
[6]  
DOBBERSTEIN P, 1991, 39TH ASMS C MASS SPE
[7]   ELECTROSPRAY IONIZATION-PRINCIPLES AND PRACTICE [J].
FENN, JB ;
MANN, M ;
MENG, CK ;
WONG, SF ;
WHITEHOUSE, CM .
MASS SPECTROMETRY REVIEWS, 1990, 9 (01) :37-70
[8]   DESIGN AND PERFORMANCE OF AN ELECTROSPRAY IONIZATION SOURCE FOR A DOUBLY-FOCUSING MAGNETIC-SECTOR MASS-SPECTROMETER [J].
GALLAGHER, RT ;
CHAPMAN, JR ;
MANN, M .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1990, 4 (10) :369-372
[9]   ATMOSPHERIC-PRESSURE IONIZATION MASS-SPECTROMETRY - DETECTION FOR THE SEPARATION SCIENCES [J].
HUANG, EC ;
WACHS, T ;
CONBOY, JJ ;
HENION, JD .
ANALYTICAL CHEMISTRY, 1990, 62 (13) :A713-+
[10]   AN ELECTROSPRAY ION-SOURCE FOR MAGNETIC-SECTOR MASS SPECTROMETERS [J].
LARSEN, BS ;
MCEWEN, CN .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1991, 2 (03) :205-211