CORRECTION FOR GEOMETRIC DISTORTION IN ECHO-PLANAR IMAGES FROM B-0 FIELD VARIATIONS

被引:1103
作者
JEZZARD, P
BALABAN, RS
机构
[1] Laboratory of Cardiac Energetics, NHLBI, National Institutes of Health, Bethesda, Maryland
关键词
ECHO PLANAR IMAGING; EPI; GEOMETRIC DISTORTION; FIELD MAP CORRECTION;
D O I
10.1002/mrm.1910340111
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A method is described for the correction of geometric distortions occurring in echo planar images. The geometric distortions are caused in large part by static magnetic field inhomogeneities, leading to pixel shifts, particularly in the phase encode direction. By characterizing the field inhomogeneities from a field map, the image can be unwarped so that accurate alignment to conventionally collected images can be made. The algorithm to perform the unwarping is described, and results from echo planar images collected at 1.5 and 4 Tesla are shown.
引用
收藏
页码:65 / 73
页数:9
相关论文
共 17 条
  • [1] TIME COURSE EPI OF HUMAN BRAIN-FUNCTION DURING TASK ACTIVATION
    BANDETTINI, PA
    WONG, EC
    HINKS, RS
    TIKOFSKY, RS
    HYDE, JS
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1992, 25 (02) : 390 - 397
  • [2] BOWTELL R, 1909, 2NS P SMR ANN M SAN, P411
  • [3] ANALYSIS OF T2 LIMITATIONS AND OFF-RESONANCE EFFECTS ON SPATIAL-RESOLUTION AND ARTIFACTS IN ECHO-PLANAR IMAGING
    FARZANEH, F
    RIEDERER, SJ
    PELC, NJ
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1990, 14 (01) : 123 - 139
  • [4] IMAGE-ANALYSIS USING MATHEMATICAL MORPHOLOGY
    HARALICK, RM
    STERNBERG, SR
    ZHUANG, XH
    [J]. IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1987, 9 (04) : 532 - 550
  • [5] DYNAMIC MAGNETIC-RESONANCE-IMAGING OF HUMAN BRAIN ACTIVITY DURING PRIMARY SENSORY STIMULATION
    KWONG, KK
    BELLIVEAU, JW
    CHESLER, DA
    GOLDBERG, IE
    WEISSKOFF, RM
    PONCELET, BP
    KENNEDY, DN
    HOPPEL, BE
    COHEN, MS
    TURNER, R
    CHENG, HM
    BRADY, TJ
    ROSEN, BR
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1992, 89 (12) : 5675 - 5679
  • [6] A SIMPLE GRAPHICAL REPRESENTATION OF FOURIER-BASED IMAGING METHODS
    LJUNGGREN, S
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1983, 54 (02) : 338 - 343
  • [7] BIOLOGICAL AND MEDICAL IMAGING BY NMR
    MANSFIELD, P
    PYKETT, IL
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1978, 29 (02) : 355 - 373
  • [8] MULTI-PLANAR IMAGE-FORMATION USING NMR SPIN ECHOES
    MANSFIELD, P
    [J]. JOURNAL OF PHYSICS C-SOLID STATE PHYSICS, 1977, 10 (03): : L55 - L58
  • [9] PERFUSION IMAGING WITH NMR CONTRAST AGENTS
    ROSEN, BR
    BELLIVEAU, JW
    VEVEA, JM
    BRADY, TJ
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1990, 14 (02) : 249 - 265
  • [10] INSTANT IMAGES OF THE HUMAN-HEART USING A NEW, WHOLE-BODY MR IMAGING-SYSTEM
    RZEDZIAN, RR