IMMUNOAFFINITY CHROMATOGRAPHY COMBINED WITH GAS-CHROMATOGRAPHY NEGATIVE-ION CHEMICAL IONIZATION MASS-SPECTROMETRY FOR THE CONFIRMATION OF FLUMETHASONE ABUSE IN THE EQUINE

被引:20
作者
STANLEY, SMR [1 ]
WILHELMI, BS [1 ]
RODGERS, JP [1 ]
BERTSCHINGER, H [1 ]
机构
[1] UNIV PRETORIA,FAC VET SCI,DEPT GENESIOL,ONDERSTEPOORT 0110,SOUTH AFRICA
来源
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS | 1993年 / 614卷 / 01期
关键词
D O I
10.1016/0378-4347(93)80225-S
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Immunoaffinity chromatography using a synthesised immunosorbent was used to extract tritiated dexamethasone (with dexamethasone carrier) from equine urine at a recovery of 81.7 +/- 8.4% (mean +/- S.D.). A method utilising this procedure coupled to cool on-column injection gas chromatography-negative ion chemical ionisation mass spectrometry is also described for the confirmation of low levels of flumethasone in equine urine samples.
引用
收藏
页码:77 / 86
页数:10
相关论文
共 42 条
  • [1] 2 CHROMATOGRAPHIC METHODS FOR THE DETERMINATION OF CORTICOSTEROIDS IN HUMAN BIOLOGICAL-FLUIDS - PHARMACOKINETIC APPLICATIONS
    ALHABET, SMH
    ROGERS, HJ
    [J]. JOURNAL OF PHARMACEUTICAL SCIENCES, 1989, 78 (08) : 660 - 666
  • [2] CROSS-LINKING OF A MONOMERIC 39/34-KDA DISPASE FRAGMENT OF VONWILLEBRAND-FACTOR (LEU-480/VAL-481-GLY-718) TO THE N-TERMINAL REGION OF THE ALPHA-CHAIN OF MEMBRANE GLYCOPROTEIN-IB ON INTACT PLATELETS WITH BIS(SULFOSUCCINIMIDYL) SUBERATE
    ANDREWS, RK
    GORMAN, JJ
    BOOTH, WJ
    CORINO, GL
    CASTALDI, PA
    BERNDT, MC
    [J]. BIOCHEMISTRY, 1989, 28 (21) : 8326 - 8336
  • [3] DETERMINATION OF ZERANOL AND BETA-ZEARALANOL IN CALF URINE BY IMMUNOAFFINITY EXTRACTION AND GAS-CHROMATOGRAPHY MASS-SPECTROMETRY AFTER REPEATED ADMINISTRATION OF ZERANOL
    BAGNATI, R
    ORIUNDI, MP
    RUSSO, V
    DANESE, M
    BERTI, F
    FANELLI, R
    [J]. JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1991, 564 (02): : 493 - 502
  • [4] ANALYSIS OF DIETHYLSTILBESTROL, DIENESTROL AND HEXESTROL IN BIOLOGICAL SAMPLES BY IMMUNOAFFINITY EXTRACTION AND GAS-CHROMATOGRAPHY NEGATIVE-ION CHEMICAL IONIZATION MASS-SPECTROMETRY
    BAGNATI, R
    CASTELLI, MG
    AIROLDI, L
    ORIUNDI, MP
    UBALDI, A
    FANELLI, R
    [J]. JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1990, 527 (02): : 267 - 278
  • [5] BERTRAND PV, 1987, CLIN CHEM, V33, P2047
  • [6] URINARY-EXCRETION OF SYNTHETIC CORTICOSTEROIDS BY HORSE
    CHAPMAN, DI
    MOSS, MS
    WHITESIDE, J
    [J]. VETERINARY RECORD, 1977, 100 (21) : 447 - 450
  • [7] RIA VS CPB FOR PREDNISOLONE
    COLBURN, WA
    BULLER, RH
    [J]. JOURNAL OF PHARMACOKINETICS AND BIOPHARMACEUTICS, 1975, 3 (05): : 329 - 332
  • [8] Cook B, 1987, STEROID HORMONES PRA, P1
  • [9] DUMASIA MC, 1980, 3RD P INT S MED CONT, P247
  • [10] ERLANGER BF, 1957, J BIOL CHEM, V228, P713