DYNAMIC ANALYSIS OF PROFUNDUS TENDON FUNCTION

被引:43
作者
GREENWALD, D [1 ]
SHUMWAY, S [1 ]
ALLEN, C [1 ]
MASS, D [1 ]
机构
[1] UNIV S FLORIDA,DEPT PLAST SURG,TAMPA,FL
来源
JOURNAL OF HAND SURGERY-AMERICAN VOLUME | 1994年 / 19A卷 / 04期
关键词
D O I
10.1016/0363-5023(94)90272-0
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
A method for analysis of hand function is reported through evaluation and characterization of flexor digitorum profundus (FDP) tendon mechanics. A testing platform is used that allows for the dynamic evaluation of intact cadaver hand mechanics under normal and pathologic conditions using simultaneous measurements of tendon load, tendon excursion, grip strength, pinch strength, and joint angle. This study of FDP tendons in normal fresh cadaver hands demonstrates that FDP tendon excursion increases as the number and size of joints flexed increases. Extensor counterweighting 500 g, increases FDP tendon load and work but not excursion requirements, and FDP loads of up to 75 N are required for single finger grip strengths of 4 kg force. These loads do not result in permanent (plastic) deformation of either the tendon or the restraining soft tissues. Detailed descriptions of the platform and the mechanical tests performed are provided.
引用
收藏
页码:626 / 635
页数:10
相关论文
共 22 条
[11]  
Lehman, Calhoun, An identified model for human wrist movements, Exp Brain Res, 81, pp. 199-208, (1990)
[12]  
Winters, Kleweno, Effect of initial upper-limb alignment on muscle contributions to isometric strength curves, Journal of Biomechanics, 26, pp. 144-153, (1993)
[13]  
Hume, Hutchinson, Jaeger, Hunter, Biomechanics of pulley reconstruction, J Hand Surg, 16 A, pp. 722-730, (1991)
[14]  
Garcia-Elias, An, Berglund, Linscheid, Cooney, Chao, Extensor mechanism of the fingers I. A quantitative geometry study, J Hand Surg, 16 A, pp. 1130-1136, (1991)
[15]  
Wainwright, Biggs, Currey, Gosline, Mechanical design in organisms, pp. 23-29, (1976)
[16]  
Brand, Hollister, Clinical mechanics of the hand, pp. 254-352, (1993)
[17]  
Abrahams, Mechanical behavior of tendon in vitro, Mol Biol Exper, 5, pp. 433-443, (1967)
[18]  
Benedict, Walker, Harris, Stress-strain characteristics and tensile strength of unembalmed human tendon, J Biomech, 1, pp. 53-63, (1968)
[19]  
Walsh, MacNab, Riley, Eng, Biomechanical studies of rabbit tendon, Clin Orthop, 81, pp. 171-177, (1971)
[20]  
Herrick, Kingsbury, Lou, A study of the normal range of strain, strain rate, and stiffness of tendon, J Biomed Mat Res, 12, pp. 877-894, (1978)