共 19 条
COMPARISON BETWEEN OXYGEN-CONSUMPTION CALCULATED BY FICKS PRINCIPLE USING A CONTINUOUS THERMODILUTION TECHNIQUE AND MEASURED BY INDIRECT CALORIMETRY
被引:32
作者:
BIZOUARN, P
[1
]
BLANLOEIL, Y
[1
]
PINAUD, M
[1
]
机构:
[1] HOP HOTEL DIEU, SERV ANESTH REANIM, NANTES, FRANCE
关键词:
OXYGEN;
CONSUMPTION;
MEASUREMENT TECHNIQUES;
CARDIAC OUTPUT;
THERMODILUTION;
CALORIMETRY;
D O I:
10.1093/bja/75.6.719
中图分类号:
R614 [麻醉学];
学科分类号:
100217 ;
摘要:
We calculated oxygen consumption by the reverse Fick principle (cVO(2)) using cardiac output measured with a new technique of continuous thermal dilution and compared these values with measurements made at the same time using a gas exchange method (mVO(2)). We studied nine patients in a stable condition after cardiac surgery. In each patient six successive measurements of continuous cardiac output and mVO(2) were made over 5 min at 10-min intervals. The mean difference between the estimates (mVO(2)-cVO(2)) was 15 ml min(-1) m(2) (95% confidence limits, -3 to 33 ml min(-1) m(2)). The relative error of each method was 5% and 4% (continuous cardiac output and gas exchange methods, respectively). Calculation of VO2 using the new cardiac output technology had good repeatability compared with direct measurement, probably because of the high precision of measurement of cardiac output.
引用
收藏
页码:719 / 723
页数:5
相关论文