Cementless bulk alumina socket - Preliminary results at 6 years

被引:25
作者
Hamadouche, M [1 ]
Nizard, RS [1 ]
Meunier, A [1 ]
Bizot, P [1 ]
Sedel, L [1 ]
机构
[1] Lariboisierre Hosp, Dept Traumatol & Orthopaed Surg, Paris, France
关键词
alumina; acetabulum; press-fit; total hip arthroplasty; survivorship analysis;
D O I
10.1016/S0883-5403(99)90225-5
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
To avoid polyethylene wear observed in total hip replacement, an alumina-alumina combination has been used since 1977. The aim of this study is to report the results of a hybrid alumina-alumina total hip arthroplasty with a cementless press-fit bulk alumina socket and a cemented titanium alloy stem in 55 patients (62 hips) operated on between 1982 and 1990. The bearing surfaces were a 32-mm alumina head articulating within the alumina socket. Four failures occurred: 3 aseptic loosenings of the socket and 1 femoral head fracture. Considering aseptic loosening as the endpoint, the survival rate was 93.2% after 6 years. At a mean of 72.1 months' follow-up, 92.4% of the surviving hips were graded as very good or good using the Merle d'Aubigne-Postel hip score. Radiolucent lines were observed on the acetabular side in 68.1 of the hips. The future of this interface, which is probably fibrous, remains questionable. With the exception of 1 femoral head fracture, all revisions were related to failure of the bony fixation of the socket, and no problem was encountered related to the alumina-alumina friction coupling. Alumina sockets with other types of cementless fixation have therefore been designed and are presently under clinical investigation.
引用
收藏
页码:701 / 707
页数:7
相关论文
共 31 条
[11]  
Gruen TA, 1979, CLIN ORTHOP RELAT R, V141, P17
[12]  
HAMADOUCHE A, 1996, 42 ANN M ORTH RES SO
[13]   Fracture of an alumina ceramic head in total hip arthroplasty [J].
Higuchi, F ;
Shiba, N ;
Inoue, A ;
Wakebe, I .
JOURNAL OF ARTHROPLASTY, 1995, 10 (06) :851-854
[14]  
KOBAYASHI S, 1994, CLIN ORTHOP RELAT R, V306, P84
[15]  
MANTEL N, 1959, J NATL CANCER I, V22, P719
[16]  
MANTEL N, 1963, J AM STAT ASSOC, V58, P690
[17]   THE EFFECT OF IMPROVED CEMENTING TECHNIQUES ON COMPONENT LOOSENING IN TOTAL HIP-REPLACEMENT - AN 11-YEAR RADIOGRAPHIC REVIEW [J].
MULROY, RD ;
HARRIS, WH .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1990, 72 (05) :757-760
[18]  
NIZARD RS, 1992, CLIN ORTHOP RELAT R, V282, P53
[19]   DESIGN AND ANALYSIS OF RANDOMIZED CLINICAL-TRIALS REQUIRING PROLONGED OBSERVATION OF EACH PATIENT .2. ANALYSIS AND EXAMPLES [J].
PETO, R ;
PIKE, MC ;
ARMITAGE, P ;
BRESLOW, NE ;
COX, DR ;
HOWARD, SV ;
MANTEL, N ;
MCPHERSON, K ;
PETO, J ;
SMITH, PG .
BRITISH JOURNAL OF CANCER, 1977, 35 (01) :1-39
[20]   Fracture of a ceramic femoral head after a revision operation - A case report [J].
Pulliam, IT ;
Trousdale, RT .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1997, 79A (01) :118-121