SIGNAL-TO-NOISE AND CONTRAST IN FAST SPIN-ECHO (FSE) AND INVERSION RECOVERY FSE IMAGING

被引:113
作者
CONSTABLE, RT
SMITH, RC
GORE, JC
机构
[1] Department of Diagnostic Radiology, Yale University, New Haven, CT, 06510
关键词
MAGNETIC RESONANCE IMAGING; TECHNIQUES; FAST SPIN ECHO (FSE); NOISE;
D O I
10.1097/00004728-199201000-00008
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Fast spin echo (FSE) imaging has recently experienced a renewed enthusiasm in the clinical setting for its ability to provide high contrast T2-weighted images in short imaging times. This article evaluates the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) properties of the FSE sequence, inversion recovery (IR) FSE sequence, and conventional SE imaging. The results indicate that FSE imaging displays similar contrast properties to SE imaging, but that the SNR and CNR are improved secondary to the longer TRs and longer effective TEs that may be used. The SNR per unit time of the FSE sequence, and hence its efficiency, is at least a factor of 8 better than the SE sequence when 16 echoes are acquired for each excitation. The addition of a slice selective inversion pulse in IR-FSE allows rapid generation of IR images with image contrast similar to that of conventional IR sequences. When used with a multicoil array for abdominal, pelvic, and spine imaging, the IR-FSE sequence produces images that are virtually free of motion artifact from the subcutaneous fat immediately adjacent to the coils. Both FSE and IR-FSE, when compared with SE imaging, provide superior image contrast and SNR in reduced imaging time.
引用
收藏
页码:41 / 47
页数:7
相关论文
共 23 条
[1]   MR IMAGING OF THE LIVER USING SHORT TI INVERSION RECOVERY SEQUENCES [J].
BYDDER, GM ;
STEINER, RE ;
BLUMGART, LH ;
KHENIA, S ;
YOUNG, IR .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1985, 9 (06) :1084-1089
[2]   STRATEGIES TO IMPROVE CONTRAST IN TURBOFLASH IMAGING - REORDERED PHASE ENCODING AND K-SPACE SEGMENTATION [J].
CHIEN, D ;
ATKINSON, DJ ;
EDELMAN, RR .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1991, 1 (01) :63-70
[3]  
CONSTABLE RT, 1991, P SMRM
[4]   ERRORS IN T2 ESTIMATION USING MULTISLICE MULTIPLE-ECHO IMAGING [J].
CRAWLEY, AP ;
HENKELMAN, RM .
MAGNETIC RESONANCE IN MEDICINE, 1987, 4 (01) :34-47
[5]   REDUCTION OF MR IMAGING TIME BY THE HYBRID FAST-SCAN TECHNIQUE [J].
HAACKE, EM ;
BEARDEN, FH ;
CLAYTON, JR ;
LINGA, NR .
RADIOLOGY, 1986, 158 (02) :521-529
[6]   FAST MR-IMAGING - TECHNIQUES AND CLINICAL-APPLICATIONS [J].
HAACKE, EM ;
TKACH, JA .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1990, 155 (05) :951-964
[7]   FLASH IMAGING - RAPID NMR IMAGING USING LOW FLIP-ANGLE PULSES [J].
HAASE, A ;
FRAHM, J ;
MATTHAEI, D ;
HANICKE, W ;
MERBOLDT, KD .
JOURNAL OF MAGNETIC RESONANCE, 1986, 67 (02) :258-266
[8]   NOISE CORRELATIONS IN DATA SIMULTANEOUSLY ACQUIRED FROM MULTIPLE SURFACE COIL ARRAYS [J].
HAYES, CE ;
ROEMER, PB .
MAGNETIC RESONANCE IN MEDICINE, 1990, 16 (02) :181-191
[9]   RARE IMAGING - A FAST IMAGING METHOD FOR CLINICAL MR [J].
HENNIG, J ;
NAUERTH, A ;
FRIEDBURG, H .
MAGNETIC RESONANCE IN MEDICINE, 1986, 3 (06) :823-833
[10]   MULTIECHO IMAGING SEQUENCES WITH LOW REFOCUSING FLIP ANGLES [J].
HENNIG, J .
JOURNAL OF MAGNETIC RESONANCE, 1988, 78 (03) :397-407