EFFECT OF THE SAMPLE SOLVENT AND INSTRUMENT DESIGN ON THE REPRODUCIBILITY OF RETENTION TIMES AND PEAK SHAPES IN PACKED-COLUMN SUPERCRITICAL-FLUID CHROMATOGRAPHY

被引:7
作者
SMITH, RM
BRIGGS, DA
机构
[1] Department of Chemistry, Loughborough University of Technology, Loughborough
关键词
D O I
10.1016/0021-9673(94)80291-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Factors affecting the reproducibility of retention times and peak shapes in supercritical fluid chromatography on a cyano-bonded silica packed column have been studied. These included the inclusion of low proportions of modifier in the eluent and the solvent used to inject the analyte. With carbon dioxide as the eluent, polar sample solvents were found to cause residual effects, which changed subsequent separations. These effects were lost when an eluent modifier was present suggesting that they resulted from temporary masking of silanol groups on the silica surface. If the mobile phase was cooled to near the critical point between the oven and a spectroscopic detector, small changes in conditions caused baseline fluctuations, which was considered to be due to changes in the refractive index of the solution.
引用
收藏
页码:161 / 171
页数:11
相关论文
共 30 条
[1]   SUPERCRITICAL FLUID CHROMATOGRAPHY IN THE ROUTINE STABILITY CONTROL OF ANTIPRURITIC PREPARATIONS [J].
ANTON, K ;
BACH, M ;
GEISER, A .
JOURNAL OF CHROMATOGRAPHY, 1991, 553 (1-2) :71-79
[2]  
ASHRAFKHORASSANI M, 1988, CHROMAT MET, P115
[3]   EFFECTS OF COLUMN AND MOBILE PHASE POLARITY USING STEROIDS AS PROBES IN PACKED-COLUMN SUPERCRITICAL FLUID CHROMATOGRAPHY [J].
BERGER, TA ;
DEYE, JF .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1991, 29 (07) :280-286
[4]   SEPARATION OF PHENOLS BY PACKED-COLUMN SUPERCRITICAL FLUID CHROMATOGRAPHY [J].
BERGER, TA ;
DEYE, JF .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1991, 29 (02) :54-59
[5]   REFRACTIVE INDEXES OF ETHANE, CARBON-DIOXIDE, AND ISOBUTANE [J].
BESSERER, GJ ;
ROBINSON, DB .
JOURNAL OF CHEMICAL AND ENGINEERING DATA, 1973, 18 (02) :137-140
[6]   MODIFIER EFFECTS ON RETENTION AND PEAK SHAPE IN SUPERCRITICAL FLUID CHROMATOGRAPHY [J].
BLILIE, AL ;
GREIBROKK, T .
ANALYTICAL CHEMISTRY, 1985, 57 (12) :2239-2242
[7]   INJECTION OF LARGE VOLUMES OF AQUEOUS-SOLUTIONS IN CAPILLARY SUPERCRITICAL FLUID CHROMATOGRAPHY AND SAMPLE PRECONCENTRATION BY MULTIPLE INJECTIONS [J].
BOUISSEL, S ;
ERNI, F ;
LINK, R .
JOURNAL OF CHROMATOGRAPHY, 1993, 630 (1-2) :307-312
[8]   ABNORMAL COMPOSITION OF COMMERCIAL WAXES REVEALED BY SUPERCRITICAL FLUID CHROMATOGRAPHY [J].
BROSSARD, S ;
LAFOSSE, M ;
DREUX, M ;
BECART, J .
CHROMATOGRAPHIA, 1993, 36 :268-274
[9]  
CHERVET JP, 1991, LC GC EUR, V4, P32
[10]   COMPARISON OF HELIUM HEAD PRESSURE CARBON-DIOXIDE AND PURE CARBON-DIOXIDE AS MOBILE PHASES IN SUPERCRITICAL FLUID CHROMATOGRAPHY [J].
GORNER, T ;
DELLACHERIE, J ;
PERRUT, M .
JOURNAL OF CHROMATOGRAPHY, 1990, 514 (02) :309-316