DETECTION OF POLIOVIRUS, HEPATITIS-A VIRUS, AND ROTAVIRUS FROM SEWAGE AND OCEAN WATER BY TRIPLER REVERSE-TRANSCRIPTASE PCR

被引:82
作者
TSAI, YL
TRAN, B
SANGERMANO, LR
PALMER, CJ
机构
关键词
D O I
10.1128/AEM.60.7.2400-2407.1994
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
A tripler reverse transcriptase PCR (RT-PCR) was developed to simultaneously detect poliovirus, hepatitis A virus (HAV), and rotavirus in sewage and ocean water. Sewage and ocean water samples seeded with the three different viruses were concentrated by ultrafiltration. The unseeded ocean water and sewage samples were concentrated by vortex flow filtration and/or ultrafiltration. Random hexamers and a rotavirus downstream primer were used to initiate reverse transcription. Three different sets of primers specific for poliovirus, HAV, and rotavirus cDNAs were mixed in the PCR mixture to amplify the target DNA. Three distinct amplified DNA products representing poliovirus, HAV, and rotavirus were identified by gel electrophoresis as 394-, 192-, and 278-bp sequences, respectively. Dot blot and Southern analyses were used to confirm the amplified products for each virus present in the environmental samples. Except for poliovirus, the sensitivity of tripler RT-PCR for the detection of rotavirus and HAV was found to be similar to that of monoplex RT-PCR, which uses only one set of primers to amplify a single type of virus. The tripler RT-PCR has greater advantages over monoplex RT-PCR for virus detection, namely, the rapid turnaround time and cost effectiveness.
引用
收藏
页码:2400 / 2407
页数:8
相关论文
共 31 条
  • [1] DETECTION OF ENTEROVIRUSES IN GROUNDWATER WITH THE POLYMERASE CHAIN-REACTION
    ABBASZADEGAN, M
    HUBER, MS
    GERBA, CP
    PEPPER, IL
    [J]. APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1993, 59 (05) : 1318 - 1324
  • [2] DETECTION OF ENTERIC VIRUSES IN OYSTERS BY USING THE POLYMERASE CHAIN-REACTION
    ATMAR, RL
    METCALF, TG
    NEILL, FH
    ESTES, MK
    [J]. APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1993, 59 (02) : 631 - 635
  • [3] MULTIPLEX PCR AMPLIFICATION AND IMMOBILIZED CAPTURE PROBES FOR DETECTION OF BACTERIAL PATHOGENS AND INDICATORS IN WATER
    BEJ, AK
    MAHBUBANI, MH
    MILLER, R
    DICESARE, JL
    HAFF, L
    ATLAS, RM
    [J]. MOLECULAR AND CELLULAR PROBES, 1990, 4 (05) : 353 - 365
  • [4] DETECTION OF COLIFORM BACTERIA IN WATER BY POLYMERASE CHAIN-REACTION AND GENE PROBES
    BEJ, AK
    STEFFAN, RJ
    DICESARE, J
    HAFF, L
    ATLAS, RM
    [J]. APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1990, 56 (02) : 307 - 314
  • [5] MOLECULAR-DETECTION AND IDENTIFICATION OF ENTEROVIRUSES USING ENZYMATIC AMPLIFICATION AND NUCLEIC-ACID HYBRIDIZATION
    CHAPMAN, NM
    TRACY, S
    GAUNTT, CJ
    FORTMUELLER, U
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1990, 28 (05) : 843 - 850
  • [6] DAVIS LG, 1986, BASIC METHODS MOL BI, P147
  • [7] De Leon R., 1990, P 1990 WAT QUAL TECH, P833
  • [8] DETECTION OF NORWALK VIRUS IN STOOL SPECIMENS BY REVERSE TRANSCRIPTASE-POLYMERASE CHAIN-REACTION AND NONRADIOACTIVE OLIGOPROBES
    DELEON, R
    MATSUI, SM
    BARIC, RS
    HERRMANN, JE
    BLACKLOW, NR
    GREENBERG, HB
    SOBSEY, MD
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1992, 30 (12) : 3151 - 3157
  • [9] APPLICATION OF THE PCR TECHNIQUE TO THE DETECTION OF HEPATITIS-A VIRUS IN THE ENVIRONMENT
    DIVIZIA, M
    MORACE, G
    GABRIELI, R
    PISANI, G
    PANA, A
    [J]. WATER SCIENCE AND TECHNOLOGY, 1993, 27 (3-4) : 223 - 225
  • [10] AMPLIFICATION OF RHINOVIRUS SPECIFIC NUCLEIC-ACIDS FROM CLINICAL-SAMPLES USING THE POLYMERASE CHAIN-REACTION
    GAMA, RE
    HORSNELL, PR
    HUGHES, PJ
    NORTH, C
    BRUCE, CB
    ALNAKIB, W
    STANWAY, G
    [J]. JOURNAL OF MEDICAL VIROLOGY, 1989, 28 (02) : 73 - 77