PSEUDOARTHROSIS RATE AFTER ALLOGRAFT POSTERIOR LUMBAR INTERBODY FUSION WITH PEDICLE SCREW AND PLATE FIXATION

被引:86
作者
BRANTIGAN, JW
机构
[1] Cleveland Spine and Arthritis Center, Cleveland, OH
[2] Division of Orthopaedic Surgery, Creighton University, Omaha, NE, 68131
关键词
ALLOGRAFT BONE; ETHYLENE OXIDE; FUSION; LUMBAR SPINE; PEDICLE SCREW; POSTERIOR LUMBAR INTERBODY FUSION; VARIABLE SCREW PLACEMENT;
D O I
10.1097/00007632-199405310-00014
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. Twenty-five of 26 consecutive patients were studied after posterior lumbar interbody fusion using ethylene oxide-sterilized allograft bone for posterior lumbar interbody fusion and autologous bone for posterolateral fusion with posterior fixation using pedicle screws and variable screw placement plates. Objectives. Patients were studied at 1 year to determine rate of complications, pseudarthrosis, and re-operations. Methods. Clinical success was determined by combined five-point analog pain and function scales. Fusion success was determined by plain radiographs. Results. Complications occurred in four of 25 patients (16%). Re-operations were done in nine of 25 patients (36%) with seven re-operations (28%) to treat frank failures of the donor bone. Although some patients subsequently improved with repeat surgery, the result of the donor bone posterior lumbar interbody fusion was excellent in nine patients, good in four, fair in eight, and poor in four. Posterior lumbar interbody fusion success was achieved in 14 of 25 patients (56%). Clinical success was achieved in 15 of 25 patients (60%). Conclusions. Although the mechanical principles of posterior lumbar interbody fusion were affirmed, the adequacy of ethylene oxide-sterilized allograft bone in meeting the mechanical and biologic needs of posterior lumbar interbody fusion was questioned.
引用
收藏
页码:1271 / 1279
页数:9
相关论文
共 40 条
  • [31] Stauffer R.N., Coventry M.B., Anterior interbody lumbar spine fusion: Analysis of Mayo Clinic series, J Bone Joint Surg Am, 54, pp. 756-768, (1972)
  • [32] Steffee A.D., The variable screw placement system with posterior lumbar interbody fusion, Lumbar Interbody Fusion: Principles and Techniques in Spine Surgery, pp. 81-93, (1989)
  • [33] Steffee A.D., Brantigan J.W., The VSP spinal fixation system Report of a prospective study of 250 patients enrolled in FDA clinical trials, Spine, 18, pp. 1160-1172, (1993)
  • [34] Steffee A.D., Sitkowski D., Posterior lumbar interbody fusion and plates, Clin Orthop, 227, pp. 99-102, (1988)
  • [35] Steffee A.D., Sitkowski D.J., Reduction and stabilization of grade IV spondylolisthesis, Clin Orthop, 227, pp. 82-89, (1988)
  • [36] Steffee A.D., Biscup R.S., Sitkowski D.J., Segmental spine plates with pedicle screw fixation, Clin Orthop, 203, pp. 45-53, (1986)
  • [37] Thompson W., Gristina A.G., Healy W.A., Lumbosacral spine fusion: A method of bilateral posterolateral fusion combined with a Hibbs fusion, J Bone Joint Surg Am, 56, pp. 1643-1647, (1974)
  • [38] Wetzel F.T., Larocca H., The failed posterior lumbar interbody fusion, Spine, 16, pp. 839-845, (1991)
  • [39] Wiltse L.L., Surgery for intervertebral disk disease of the lumbar spine, Clin Orthop, 129, pp. 22-45, (1977)
  • [40] Zinreich S.J., Long D.M., Davis R., Quinn C.B., McAfee P.C., Wang H., Three-dimensional CT imaging in postsurgical “failed back” syndrome, J Comput Assist Tomogr, 14, pp. 574-580, (1990)