FUMED-SILICA CONTAINING CARBON-PASTE DEHYDROGENASE BIOSENSORS

被引:46
作者
WANG, J
LIU, J
机构
[1] Department of Chemistry and Biochemistry, New Mexico State University, Las Cruces
关键词
BIOSENSORS; ALCOHOL; FUMED SILICA; LACTATE;
D O I
10.1016/0003-2670(93)85324-D
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The sensitivity and stability of dehydrogenase-based carbon paste biosensors art greatly improved upon adding fumed-silica nanoparticles into the electrode matrix. The enhanced performance is attributed to improved retention of the dehydrogenases and their NAD(+) cofactor on the silica support, and to an electrocatalytic action of fumed silica towards the detection of NADH. Such advantages of the silica modified carbon paste are illustrated with the enzymes alcohol and lactate dehydrogenase, and using batch and flow conditions. The response is characterized with respect to various experimental variables.
引用
收藏
页码:385 / 391
页数:7
相关论文
共 10 条
[1]   STUDY OF A REAGENTLESS LACTATE ELECTRODE [J].
BLAEDEL, WJ ;
JENKINS, RA .
ANALYTICAL CHEMISTRY, 1976, 48 (08) :1240-1247
[2]   AN AMPEROMETRIC GLUCOSE ELECTRODE BASED ON CARBON PASTE, CHEMICALLY MODIFIED WITH GLUCOSE-DEHYDROGENASE, NICOTINAMIDE ADENINE-DINUCLEOTIDE, AND A PHENOXAZINE MEDIATOR, COATED WITH A POLY(ESTER SULFONIC-ACID) CATION EXCHANGER [J].
BREMLE, G ;
PERSSON, B ;
GORTON, L .
ELECTROANALYSIS, 1991, 3 (02) :77-86
[3]   AMPEROMETRIC BIOSENSORS BASED ON AN APPARENT DIRECT ELECTRON-TRANSFER BETWEEN ELECTRODES AND IMMOBILIZED PEROXIDASES - PLENARY LECTURE [J].
GORTON, L ;
JONSSONPETTERSSON, G ;
CSOREGI, E ;
JOHANSSON, K ;
DOMINGUEZ, E ;
MARKOVARGA, G .
ANALYST, 1992, 117 (08) :1235-1241
[4]   CHEMICALLY MODIFIED ELECTRODES FOR THE ELECTROCATALYTIC OXIDATION OF NICOTINAMIDE COENZYMES [J].
GORTON, L .
JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS I, 1986, 82 :1245-1258
[5]  
GRUMBLISS A, 1988, BIOTECHNOL BIOENG, V31, P796
[6]   YEAST-BASED CARBON PASTE BIOELECTRODE FOR ETHANOL [J].
KUBIAK, WW ;
WANG, J .
ANALYTICA CHIMICA ACTA, 1989, 221 (01) :43-51
[7]   DEHYDROGENASE-MODIFIED CARBON-FIBER MICROELECTRODES FOR THE MEASUREMENT OF NEUROTRANSMITTER DYNAMICS .2. COVALENT MODIFICATION UTILIZING AVIDIN BIOTIN TECHNOLOGY [J].
PANTANO, P ;
KUHR, WG .
ANALYTICAL CHEMISTRY, 1993, 65 (05) :623-630
[8]   RENEWABLE ALCOHOL BIOSENSORS BASED ON ALCOHOL-DEHYDROGENASE NICOTINAMIDE-ADENINE-DINUCLEOTIDE GRAPHITE EPOXY ELECTRODES [J].
WANG, J ;
GONZALEZROMERO, E ;
OZSOZ, M .
ELECTROANALYSIS, 1992, 4 (05) :539-544
[9]  
WANG J, IN PRESS ELECTROANAL
[10]   ELECTROOXIDATIVE CATALYSIS USING DISPERSED ALUMINA ON GLASSY-CARBON SURFACES [J].
ZAK, J ;
KUWANA, T .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1982, 104 (20) :5514-5515