LINE SCANNING SYSTEM FOR DIRECT DIGITAL CHEMILUMINESCENCE IMAGING OF DNA-SEQUENCING BLOTS

被引:14
作者
KARGER, AE
WEISS, R
GESTELAND, RF
机构
[1] UNIV UTAH, DEPT HUMAN GENET, SALT LAKE CITY, UT 84112 USA
[2] UNIV UTAH, HOWARD HUGHES MED INST, SALT LAKE CITY, UT 84112 USA
[3] ECCLES INST HUMAN GENET, SALT LAKE CITY, UT 84112 USA
关键词
D O I
10.1021/ac00061a024
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A cryogenically cooled charge-coupled device (CCD) camera equipped with an area CCD array is used in a line scanning system for low-light-level imaging of chemiluminescent DNA sequencing blots. Operating the CCD camera in time-delayed integration (TDI) mode results in continuous data acquisition independent of the length of the CCD array. Scanning is possible with a resolution of 1.4 line pairs/mm at the 50% level of the modulation transfer function. High-sensitivity, low-light-level scanning of chemiluminescent direct-transfer electrophoresis (DTE) DNA sequencing blots is shown. The detection of DNA fragments on the blot involves DNA-DNA hybridization with oligonucleotide-alkaline phosphatase conjugate and 1,2-dioxetane-based chemiluminescence. The width of the scan allows the recording of up to four sequencing reactions (16 lanes) on one scan. The scan speed of 52 cm/h used for the sequencing blots corresponds to a data acquisition rate of 384 pixels/s. The chemiluminescence detection limit on the scanned images is 3.9 X 10(-18) mol of plasmid DNA. A conditional median filter is described to remove spikes caused by cosmic ray events from the CCD images.
引用
收藏
页码:1785 / 1793
页数:9
相关论文
共 39 条
[1]   THOMSON-CSF FRAME-TRANSFER CHARGE-COUPLED-DEVICE IMAGERS - DESIGN AND EVALUATION AT VERY LOW FLUX LEVEL [J].
BEAL, G ;
BOUCHARLAT, G ;
CHABBAL, J ;
DUPIN, JP ;
FORT, B ;
MELLIER, Y .
OPTICAL ENGINEERING, 1987, 26 (09) :902-910
[2]   COLORIMETRIC-DETECTED DNA SEQUENCING [J].
BECK, S .
ANALYTICAL BIOCHEMISTRY, 1987, 164 (02) :514-520
[3]   APPLICATIONS OF DIOXETANE CHEMILUMINESCENT PROBES TO MOLECULAR-BIOLOGY [J].
BECK, S ;
KOSTER, H .
ANALYTICAL CHEMISTRY, 1990, 62 (21) :2258-2270
[4]   THE USE OF CHARGE-COUPLED-DEVICES IN THE QUANTITATIVE-EVALUATION OF IMAGES, ON PHOTOGRAPHIC FILM OR MEMBRANES, OBTAINED FOLLOWING ELECTROPHORETIC SEPARATION OF DNA FRAGMENTS [J].
BONISZEWSKI, ZAM ;
COMLEY, JS ;
HUGHES, B ;
READ, CA .
ELECTROPHORESIS, 1990, 11 (05) :432-440
[5]  
CAMPION A, 1990, LASER FOCUS WORLD, V8, P113
[6]   A MAJOR SEGMENT OF THE NEUROFIBROMATOSIS TYPE-1 GENE - CDNA SEQUENCE, GENOMIC STRUCTURE, AND POINT MUTATIONS [J].
CAWTHON, RM ;
WEISS, R ;
XU, GF ;
VISKOCHIL, D ;
CULVER, M ;
STEVENS, J ;
ROBERTSON, M ;
DUNN, D ;
GESTELAND, R ;
OCONNELL, P ;
WHITE, R .
CELL, 1990, 62 (01) :193-201
[7]   ONLINE DETECTION OF DNA IN GEL-ELECTROPHORESIS BY ULTRAVIOLET-ABSORPTION UTILIZING A CHARGE-COUPLED DEVICE IMAGING-SYSTEM [J].
CHAN, KC ;
KOUTNY, LB ;
YEUNG, ES .
ANALYTICAL CHEMISTRY, 1991, 63 (07) :746-750
[8]   MULTIPLEX DNA SEQUENCING [J].
CHURCH, GM ;
KIEFFERHIGGINS, S .
SCIENCE, 1988, 240 (4849) :185-188
[9]  
CREASEY A, 1991, BIOTECHNIQUES, V11, P102
[10]   BINNING SPECTRAL IMAGES IN A CHARGE-COUPLED DEVICE [J].
EPPERSON, PM ;
DENTON, MB .
ANALYTICAL CHEMISTRY, 1989, 61 (14) :1513-1519