MASS AND CHARGE-TRANSFER KINETICS AND COULOMETRIC CURRENT EFFICIENCIES .8. SINGLE-SCAN VOLTAMMETRY OF VANADIUM(V) - VANADIUM(IV) IN PRESENCE OF CHROMIUM, MANGANESE AND IRON, AND KINETIC PARAMETERS OF VANADIUM SYSTEM, AT PLATINUM-ELECTRODES PRETREATED BY 5 METHODS

被引:9
作者
BISHOP, E [1 ]
HITCHCOC.PH [1 ]
机构
[1] UNIV EXETER,CHEM DEPT,STOCKER RD,EXETER EX4,ENGLAND
关键词
D O I
10.1039/an9739800563
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
引用
收藏
页码:563 / 571
页数:9
相关论文
共 14 条
[1]   EFFECT OF SURFACE OXIDATION AND PLATINIZATION ON BEHAVIOR OF PLATINUM ELECTRODES - REDUCTION OF VANADIUM(V) AND IODATE [J].
ANSON, FC ;
KING, DM .
ANALYTICAL CHEMISTRY, 1962, 34 (03) :362-&
[2]   MASS AND CHARGE-TRANSFER KINETICS AND COULOMETRIC CURRENT EFFICIENCIES .6. PRETREATMENT OF SOLID ELECTRODES, AND A REVIEW OF EFFECTS OF OXIDATION OF PLATINUM [J].
BISHOP, E ;
HITCHCOC.PH .
ANALYST, 1973, 98 (1168) :475-484
[3]   PRECISE COULOMETRIC DETERMINATION OF ACIDS IN CELLS WITHOUT LIQUID JUNCTION .3. DETERMINATION OF SILVER ERROR BY AMPEROSTATIC ANODIC STRIPPING [J].
BISHOP, E ;
RILEY, M .
ANALYST, 1973, 98 (1167) :416-425
[4]   MASS AND CHARGE-TRANSFER KINETICS AND COULOMETRIC CURRENT EFFICIENCIES .5. COMPARISON OF PATTERN THEORY, TAFEL, ALLEN AND HICKLING AND LEWARTOWICZ METHODS, AND APPARATUS AND PROCEDURES FOR RAMPING VOLTAMMETRY [J].
BISHOP, E ;
HITCHCOC.PH .
ANALYST, 1973, 98 (1168) :465-474
[5]   MASS AND CHARGE-TRANSFER KINETICS AND COULOMETRIC CURRENT EFFICIENCIES .8. SINGLE-SCAN VOLTAMMETRY OF VANADIUM(V) - VANADIUM(IV) IN PRESENCE OF CHROMIUM, MANGANESE AND IRON, AND KINETIC PARAMETERS OF VANADIUM SYSTEM, AT PLATINUM-ELECTRODES PRETREATED BY 5 METHODS [J].
BISHOP, E ;
HITCHCOC.PH .
ANALYST, 1973, 98 (1169) :563-571
[6]   MASS AND CHARGE-TRANSFER KINETICS AND COULOMETRIC CURRENT EFFICIENCIES .7. CONDITIONAL POTENTIALS, AND SINGLE-SCAN VOLTAMMETRY OF PURE VANADIUM(V) - VANADIUM(IV) SYSTEMS IN VARIOUS MEDIA AT PLATINUM-ELECTRODES PRETREATED BY 5 METHODS [J].
BISHOP, E ;
HITCHCOC.PH .
ANALYST, 1973, 98 (1169) :553-562
[7]   PRECISE COULOMETRIC DETERMINATION OF ACIDS IN CELLS WITHOUT LIQUID JUNCTION .1. INTRODUCTION AND INSTRUMENTATION [J].
BISHOP, E ;
RILEY, M .
ANALYST, 1973, 98 (1166) :305-312
[8]   COULOMETRIC TITRATION OF MICROGRAM QUANTITIES OF VANADIUM IN URANIUM [J].
FURMAN, NH ;
REILLEY, CN ;
COOKE, WD .
ANALYTICAL CHEMISTRY, 1951, 23 (11) :1665-1667
[9]  
ISRAEL Y, 1964, J ELECTROANAL CHEM, V8, P99
[10]   COULOMETRIC TITRATION OF URANIUM AND URANIUM-VANADIUM MIXTURES WITH +3 TITANIUM [J].
KENNEDY, JH ;
LINGANE, JJ .
ANALYTICA CHIMICA ACTA, 1958, 18 (03) :240-244