THE DESIGN AND PERFORMANCE-CHARACTERISTICS OF A MULTILEAF COLLIMATOR

被引:157
作者
JORDAN, TJ [1 ]
WILLIAMS, PC [1 ]
机构
[1] HOLT RADIUM INST,MANCHESTER M20 9BX,LANCS,ENGLAND
关键词
D O I
10.1088/0031-9155/39/2/002
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A multileaf collimator, which has been in routine clinical use for both conventional and conformal radiotherapy for over four years, is described in detail. The collimator replaces the conventional treatment head of a Philips SL. series linear accelerator and comprises 80 tungsten leaves and two orthogonal pairs of back-up collimators. Each leaf projects a width of 1 cm in the isocentric plane, allowing shaped photon treatment beams of up to 40 cm square. The performance of the prototype and first production model have been thoroughly tested against the design specifications and the requirements of IEC standards. Radiation attenuation by the collimator components has been measured and substantially exceeds those requirements. The irregular portion of a field (shielded by the leaves only) receives, on average, a dose of less than 2% of the tumour dose. The effect on the penumbra of using leaves which translate linearly and have curved faces has been assessed and found not to degrade the sharpness of the beam fall-off significantly. The reproducibility of the video system used in positioning the leaves has been measured and gave a root mean square deviation of less than 0.3 mm in repeat setting of a 10 cm square field, and an accuracy always within 1 mm. The rationale for clinical use of the device is discussed and its effect on treatment quality control and reliability, is considered.
引用
收藏
页码:231 / 251
页数:21
相关论文
共 41 条
[1]  
Aoki Y, 1987, Radiat Med, V5, P131
[2]  
BOESECKE R, 1988, STRAHLENTHER ONKOL, V164, P151
[3]   MODIFICATION OF A 3-DIMENSIONAL TREATMENT PLANNING SYSTEM FOR THE USE OF MULTI-LEAF COLLIMATORS IN CONFORMATION RADIOTHERAPY [J].
BOESECKE, R ;
BECKER, G ;
ALANDT, K ;
PASTYR, O ;
DOLL, J ;
SCHLEGEL, W ;
LORENZ, WJ .
RADIOTHERAPY AND ONCOLOGY, 1991, 21 (04) :261-268
[4]   CONFORMATION THERAPY AT THE ROYAL FREE HOSPITAL - A PROGRESS REPORT ON THE TRACKING COBALT PROJECT [J].
BRACE, JA ;
DAVY, TJ ;
SKEGGS, DBL ;
WILLIAMS, HS .
BRITISH JOURNAL OF RADIOLOGY, 1981, 54 (648) :1068-1074
[5]   DESIGN PRINCIPLES AND CLINICAL POSSIBILITIES WITH A NEW GENERATION OF RADIATION-THERAPY EQUIPMENT - A REVIEW [J].
BRAHME, A .
ACTA ONCOLOGICA, 1987, 26 (06) :403-412
[6]  
BRAHME A, 1988, STRAHLENTHER ONKOL, V164, P343
[7]  
BRAHME A, 1983, Radiotherapy and Oncology, V1, P65, DOI 10.1016/S0167-8140(83)80008-5
[8]   DOSE OPTIMIZATION WITH COMPUTER-CONTROLLED GANTRY ROTATION, COLLIMATOR MOTION AND DOSE-RATE VARIATION [J].
CHIN, LM ;
KIJEWSKI, PK ;
SVENSSON, GK ;
BJARNGARD, BE .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1983, 9 (05) :723-729
[9]  
DAVY TJ, 1979, BRIT J RADIOL, V53, P384
[10]   THE EFFECT OF SECONDARY-ELECTRON SPREAD ON THE PENUMBRA IN HIGH-ENERGY PHOTON-BEAM THERAPY [J].
DAY, MJ ;
LAMBERT, GD ;
LOCKS, SM .
BRITISH JOURNAL OF RADIOLOGY, 1990, 63 (748) :278-285