SIMULTANEOUS QUANTITATION OF OXIDIZED AND REDUCED GLUTATHIONE IN EQUINE BIOLOGICAL-FLUIDS BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING ELECTROCHEMICAL DETECTION

被引:72
作者
SMITH, NC [1 ]
DUNNETT, M [1 ]
MILLS, PC [1 ]
机构
[1] ANIM HLTH TRUST,DEPT PHYSIOL,NEWMARKET CB8 7DW,SUFFOLK,ENGLAND
来源
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS | 1995年 / 673卷 / 01期
关键词
D O I
10.1016/0378-4347(95)00245-E
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A change in the ratio of reduced glutathione (GSH) to oxidized glutathione (GSSG) can be used to indicate oxidative stress in vivo. A rapid and highly sensitive isocratic reversed-phase high-performance liquid chromatographic method using coulometric electrochemical detection (LCEC) has been developed to simultaneously detect GSH and GSSG in equine biological fluids. Perchloric acid was used to extract GSH and GSSG from equine plasma and haemolysates, and methanol was used to deproteinise bronchoalveolar lavage fluid samples. Injection of extracts onto a Hypersil ODS HPLC column produced well resolved peaks corresponding to GSH and GSSG. The concentrations of GSH and GSSG found in equine haemolysates were similar to those previously found in humans and laboratory animals, although, to the authors' knowledge, previous attempts to measure GSH and GSSG in bronchoalveolar lavage fluid using LCEC have been unsuccessful. This method can be used to measure the GSH redox ratio in biological fluids during physiological conditions that may induce oxidative stress, such as exercise and disease.
引用
收藏
页码:35 / 41
页数:7
相关论文
共 22 条
[1]  
ADAMS JD, 1983, J PHARMACOL EXP THER, V227, P749
[2]  
ANDERSON ME, 1980, J BIOL CHEM, V255, P9530
[3]   A HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY METHOD FOR MEASUREMENT OF OXIDIZED GLUTATHIONE IN BIOLOGICAL SAMPLES [J].
ASENSI, M ;
SASTRE, J ;
PALLARDO, FV ;
DELAASUNCION, JG ;
ESTRELA, JM ;
VINA, J .
ANALYTICAL BIOCHEMISTRY, 1994, 217 (02) :323-328
[4]   DETERMINATION OF GLUTATHIONE IN BIOLOGICAL TISSUES BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION [J].
BOUSQUET, E ;
SANTAGATI, NA ;
LANCETTA, T .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1989, 7 (05) :643-647
[5]   OXIDIZED GLUTATHIONE IS INCREASED IN THE ALVEOLAR FLUID OF PATIENTS WITH THE ADULT-RESPIRATORY-DISTRESS-SYNDROME [J].
BUNNELL, E ;
PACHT, ER .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1993, 148 (05) :1174-1178
[6]   NORMAL ALVEOLAR EPITHELIAL LINING FLUID CONTAINS HIGH-LEVELS OF GLUTATHIONE [J].
CANTIN, AM ;
NORTH, SL ;
HUBBARD, RC ;
CRYSTAL, RG .
JOURNAL OF APPLIED PHYSIOLOGY, 1987, 63 (01) :152-157
[7]   GLUTATHIONE AND CYSTEINE MEASUREMENT IN BIOLOGICAL SAMPLES BY HPLC WITH A GLASSY-CARBON WORKING DETECTOR [J].
CARVALHO, FD ;
REMIAO, F ;
VALE, P ;
TIMBRELL, JA ;
BASTOS, ML ;
FERREIRA, MA .
BIOMEDICAL CHROMATOGRAPHY, 1994, 8 (03) :134-136
[8]   BLOOD GLUTATHIONE OXIDATION DURING HUMAN EXERCISE [J].
GOHIL, K ;
VIGUIE, C ;
STANLEY, WC ;
BROOKS, GA ;
PACKER, L .
JOURNAL OF APPLIED PHYSIOLOGY, 1988, 64 (01) :115-119
[10]   THE SIMULTANEOUS DETERMINATION OF OXIDIZED AND REDUCED GLUTATHIONES IN LIVER-TISSUE BY ION-PAIRING REVERSE PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH A COULOMETRIC ELECTROCHEMICAL DETECTOR [J].
HARVEY, PRC ;
ILSON, RG ;
STRASBERG, SM .
CLINICA CHIMICA ACTA, 1989, 180 (03) :203-212