GLUTATHIONE AND CYSTEINE MEASUREMENT IN BIOLOGICAL SAMPLES BY HPLC WITH A GLASSY-CARBON WORKING DETECTOR

被引:52
作者
CARVALHO, FD
REMIAO, F
VALE, P
TIMBRELL, JA
BASTOS, ML
FERREIRA, MA
机构
[1] UNIV PORTO, FAC PHARM, BROMATOL LAB, P-4000 OPORTO, PORTUGAL
[2] UNIV LONDON SCH PHARM, DEPT TOXICOL, LONDON, ENGLAND
关键词
D O I
10.1002/bmc.1130080308
中图分类号
Q5 [生物化学];
学科分类号
071010 [生物化学与分子生物学]; 081704 [应用化学];
摘要
An HPLC method using a glassy carbon working detector for measuring cysteine and reduced glutathione (GSH) in biological samples was developed. Oxidized glutathione (GSSG) was also measured after reduction with glutathione reductase. This study was conducted in human plasma. Cysteine and GSH standard curves were linear in the physiological range, presenting detection limits of 22.0 pmol and 6.0 pmol respectively. Plasmatic results found were 43.92 +/- 4.15, 4.50 +/- 0.65, and 0.19 +/- 0.12 mM (means +/- SE), for cysteine, GSH and GSSG, respectively. Peak specificity for cysteine and reduced glutathione was certified by their disappearance after treatment with N-ethylmaleimide.
引用
收藏
页码:134 / 136
页数:3
相关论文
共 23 条
[1]
ADAMS JD, 1983, J PHARMACOL EXP THER, V227, P749
[2]
DIVERGENT EFFECTS OF INTRAVENOUS GSH AND CYSTEINE ON RENAL AND HEPATIC GSH [J].
AEBI, S ;
LAUTERBURG, BH .
AMERICAN JOURNAL OF PHYSIOLOGY, 1992, 263 (02) :R348-R352
[3]
DUAL ELECTRODE LIQUID-CHROMATOGRAPHY DETECTOR FOR THIOLS AND DISULFIDES [J].
ALLISON, LA ;
SHOUP, RE .
ANALYTICAL CHEMISTRY, 1983, 55 (01) :8-12
[4]
REDUCED AND OXIDIZED GLUTATHIONE EFFLUX FROM LIVER [J].
BARTOLI, GM ;
SIES, H .
FEBS LETTERS, 1978, 86 (01) :89-91
[5]
DETERMINATION OF GLUTATHIONE IN BIOLOGICAL TISSUES BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION [J].
BOUSQUET, E ;
SANTAGATI, NA ;
LANCETTA, T .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1989, 7 (05) :643-647
[6]
MEASUREMENT OF TISSUE SULFHYDRYLS AND DISULFIDES IN TISSUE PROTEIN AND NONPROTEIN FRACTIONS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING ELECTROCHEMICAL DETECTION [J].
DUPUY, D ;
SZABO, S .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1987, 10 (01) :107-119
[7]
TISSUE SULFHYDRYL GROUPS [J].
ELLMAN, GL .
ARCHIVES OF BIOCHEMISTRY AND BIOPHYSICS, 1959, 82 (01) :70-77
[8]
SEPARATION OF REDUCED AND OXIDIZED GLUTATHIONE IN A PHARMACEUTICAL PREPARATION BY ION-INTERACTION REVERSED-PHASE HPLC [J].
GENNARO, MC ;
ABRIGO, C .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1992, 10 (01) :61-65
[9]