NUMBER-AVERAGE MOLECULAR-WEIGHT AND FUNCTIONALITY OF POLY(TETRAMETHYLENE GLYCOL) BY MULTIDETECTOR SEC

被引:10
作者
HARRISON, CA
MOUREY, TH
机构
[1] Analytical Technology Division, Research Laboratories, Eastman Kodak Company, Rochester, New York
关键词
D O I
10.1002/app.1995.070560211
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
Multidetector size exclusion chromatography (SEC) is used to simultaneously determine molecular weight and number of reactive end groups per chain (functionality) of poly(tetramethylene glycol)s. Hydroxyl groups are first quantitatively derivatized with phenyl isocyanate, providing an end-group-selective UV-absorbing tag. The number of end groups per chain is then determined from the SEC chromatogram using a UV detector. Molecular weight at each retention volume and the number-average molecular weight of the whole polymer are calculated by four methods involving (1) a concentration detector and a narrow standard log M calibration curve, (2) the UV detector and a narrow standard log M calibration, (3) a viscometry detector and a universal calibration curve, and (4) combined differential viscometry and concentration detectors using a universal calibration curve. The multidetector experiment provides a unique opportunity to assess the accuracy and limitations of each approach on low-molecular-weight polymers. In particular, the effect of end groups on the concentration detector response and the application of universal calibration principles at small molecular sizes are important factors. It is shown that the concentration response can be corrected by a simple relationship between detector response and reciprocal molecular weight. Also, the quality of calibration curves is critical to the calculation of accurate molecular weights. In general, log M calibration curves provide superior results to universal calibration methods. (C) 1995 John Wiley and Sons, Inc.
引用
收藏
页码:211 / 220
页数:10
相关论文
共 13 条
[1]   FUNCTIONALITY DISTRIBUTION OF HYDROXYL-TERMINATED POLYBUTADIENES USING GEL-PERMEATION CHROMATOGRAPHY .1. METHOD AND CALIBRATION PROCEDURE [J].
ANDERSON, JN ;
BACZEK, SK ;
ADAMS, HE ;
VESCELIUS, LE .
JOURNAL OF APPLIED POLYMER SCIENCE, 1975, 19 (08) :2255-2267
[2]   FUNCTIONALITY DISTRIBUTION OF HYDROXYL-TERMINATED POLYBUTADIENES USING GEL-PERMEATION CHROMATOGRAPHY .2. MEASUREMENTS FOR COMMERCIAL POLYMERS [J].
BACZEK, SK ;
ANDERSON, JN ;
ADAMS, HE .
JOURNAL OF APPLIED POLYMER SCIENCE, 1975, 19 (08) :2269-2277
[3]   NUMBER-AVERAGE MOLECULAR-WEIGHT BY SIZE-EXCLUSION CHROMATOGRAPHY [J].
BALKE, ST ;
MOUREY, TH ;
HARRISON, CA .
JOURNAL OF APPLIED POLYMER SCIENCE, 1994, 51 (12) :2087-2102
[4]  
GARCIARUBIO LH, 1984, MACROMOLECULES, V17, P1998
[5]  
GOLDWASSER JM, 1993, ACS SYM SER, V521, P243
[6]  
GOLDWASSER JM, 1989, P INT GEL PERMEATION, P150
[7]  
MANOLOVA NE, 1985, POLYM BULL, V13, P285
[8]   SIZE EXCLUSION CHROMATOGRAPHY CALIBRATION ASSESSMENT UTILIZING COUPLED MOLECULAR-WEIGHT DETECTORS [J].
MOUREY, TH ;
MILLER, SM ;
BALKE, ST .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1990, 13 (03) :435-452
[9]   STUDIES ON THE FUNCTIONALITY DISTRIBUTION OF HYDROXYL-TERMINATED POLYBUTADIENE AND CORRELATION WITH MECHANICAL-PROPERTIES [J].
NINAN, KN ;
BALAGANGADHARAN, VP ;
CATHERINE, KB .
POLYMER, 1991, 32 (04) :628-635
[10]   PHENYL ISOCYANATE METHOD FOR DETERMINATION OF HYDROXYL EQUIVALENT WEIGHTS OF POLYOXYALKYLENE COMPOUNDS [J].
REED, DH ;
CRITCHFIELD, FE ;
ELDER, DK .
ANALYTICAL CHEMISTRY, 1963, 35 (04) :571-&