LIPOSOME-ENCAPSULATED HEMOGLOBIN USING FILM HYDRATION PROCESSING TO FORM ARTIFICIAL RED-BLOOD-CELLS

被引:9
作者
DESHPANDE, SV
BEISSINGER, RL
机构
[1] Department of Chemical Engineering, Illinois Institute of Technology, Chicago
来源
BIOMATERIALS ARTIFICIAL CELLS AND IMMOBILIZATION BIOTECHNOLOGY | 1993年 / 21卷 / 02期
关键词
D O I
10.3109/10731199309117352
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Process parameters using a Microfluidizer(TM) M110 to produce liposome-encapsulated hemoglobin (LEH) were further studied to examine their effect on hemoglobin (Hb) encapsulation efficiency (yield), steady shear viscosity, mechanical stability, and oxygen delivery. Liposome formulation loading ratios of up to 300 mumol of lipid per ml of Hb solution were evaluated; a maximum yield was obtained at 300 mumol/ml. Liposomes containing encapsulated Hb concentrations as high as 15.5 g/100 ml were prepared. LEH particle size distribution, determined from negatively stained whole mount preparations using transmission electron microscopy, resulted in average vesicle sizes for optimal batches of about 155 nm. Steady shear viscosity of LEH (up to 40% by volume) in an isotonic-isooncotic solution of PBS containing either albumin or dextran were evaluated for shear rates to 2000 s-1. Values obtained were generally higher than those of whole blood at all shear rates tested. Little leakage of Hb from liposomes stored in isotonic PBS was observed as a function of storage time and shear rate. Administration of LEH supported life in rats whose hematocrit had been reduced via isovolemic exchange transfusion to levels well below 5%, which was incompatible with survival when exchange transfusion was performed with the isotonic-isooncotic PBS solution.
引用
收藏
页码:135 / 151
页数:17
相关论文
共 58 条
[21]   A PROCEDURE FOR THE EFFICIENT ENTRAPMENT OF DRUGS IN DEHYDRATION-REHYDRATION LIPOSOMES (DRVS) [J].
GREGORIADIS, G ;
DASILVA, H ;
FLORENCE, AT .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 1990, 65 (03) :235-242
[22]  
GRUBER UF, 1969, BLOOD REPLACEMENT
[23]  
HAYWARD JA, 1982, FEBS LETT, V187, P261
[24]  
HUESTIS W, 1976, PRACTICAL BLOOD TRAN
[25]   SYNTHESIS AND EVALUATION OF A PROTOTYPAL ARTIFICIAL RED-CELL [J].
HUNT, CA ;
BURNETTE, RR ;
MACGREGOR, RD ;
STRUBBE, AE ;
LAU, DT ;
TAYLOR, N ;
KIWADA, H .
SCIENCE, 1985, 230 (4730) :1165-1168
[26]   PREPARATION OF HEMOGLOBIN-CONTAINING LIPOSOMES USING OCTYL GLUCOSIDE AND OCTYLTETRAOXYETHYLENE [J].
JOPSKI, B ;
PIRKL, V ;
JARONI, HW ;
SCHUBERT, R ;
SCHMIDT, KH .
BIOCHIMICA ET BIOPHYSICA ACTA, 1989, 978 (01) :79-84
[27]  
KATO A, 1987, ADV BIOMEDICAL POLYM
[28]  
KAY DH, 1965, TECHNIQUES ELECTRON
[29]   EFFECTS OF PARTIAL AND TOTAL ISOVOLEMIC EXCHANGE-TRANSFUSION IN FULLY CONSCIOUS RATS USING PYRIDOXYLATED POLYHEMOGLOBIN SOLUTION AS A COLLOIDAL OXYGEN-DELIVERING BLOOD REPLACEMENT FLUID [J].
KEIPERT, PE ;
CHANG, TMS .
VOX SANGUINIS, 1987, 53 (01) :7-14
[30]  
LIGLER FS, 1989, RED CELL, P435