ENHANCEMENT EFFECTS OF A HEPATOCYTE RECEPTOR-SPECIFIC MR CONTRAST AGENT IN AN ANIMAL-MODEL

被引:10
作者
SMALL, WC
NELSON, RC
SHERBOURNE, GM
BERNARDINO, ME
机构
[1] Department of Radiology, Emory University School of Medicine, Atlanta, Georgia, 30322
来源
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING | 1994年 / 4卷 / 03期
关键词
CONTRAST ENHANCEMENT; CONTRAST MEDIA; EXPERIMENTAL STUDIES; IRON; LIVER; SPLEEN;
D O I
10.1002/jmri.1880040317
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The enhancement characteristics of the liver and spleen produced by a hepatocyte-specific magnetic resonance imaging agent, an arabinogalactan-coated ultrasmall superparamagnetic iron oxide derivative, BMS 180550, were evaluated. Both heavily T1- and T2-weighted sequences were used. Imaging was performed in the farm pig model, as a function of contrast agent concentration (5, 10, and 20 mumol of iron per kilogram) and delay (immediate, 0.5, 2.5, 5.0, 7.5, and 9.0 hours) after bolus injection of BMS 180550. BMS 180550 provided excellent contrast enhancement characteristics by producing marked positive enhancement with T1-weighted sequences and marked negative enhancement with T2-weighted sequences. The T1-weighted enhancement immediately after contrast agent injection was of greater magnitude in the spleen (329% +/- 83) than in the liver (66% +/- 16). Postcontrast negative enhancement with T2-weighted sequences was largely hepatocyte specific at 5 and 10 mumol/kg but was also seen within the spleen at 20 mumol/kg. The authors discuss the possible mechanisms that produce these changes and conclude that 10 mumol/kg BMS 180550 is near the optimum dose for maximizing the enhancement properties of this agent with all sequences in the farm pig.
引用
收藏
页码:325 / 330
页数:6
相关论文
共 10 条
[1]   CLINICAL-APPLICATION OF SUPERPARAMAGNETIC IRON-OXIDE TO MR IMAGING OF TISSUE PERFUSION IN VASCULAR LIVER-TUMORS [J].
HAHN, PF ;
STARK, DD ;
WEISSLEDER, R ;
ELIZONDO, G ;
SAINI, S ;
FERRUCCI, JT .
RADIOLOGY, 1990, 174 (02) :361-366
[2]  
OTTE MT, 1992, RADIOLOGY, V185, P177
[3]   ASIALOGLYCOPROTEIN RECEPTOR FUNCTION IN BENIGN LIVER-DISEASE - EVALUATION WITH MR IMAGING [J].
REIMER, P ;
WEISSLEDER, R ;
LEE, AS ;
BUETTNER, S ;
WITTENBERG, J ;
BRADY, TJ .
RADIOLOGY, 1991, 178 (03) :769-774
[4]   DYNAMIC SIGNAL INTENSITY CHANGES IN LIVER WITH SUPERPARAMAGNETIC MR CONTRAST AGENTS [J].
REIMER, P ;
KWONG, KK ;
WEISSKOFF, R ;
COHEN, MS ;
BRADY, TJ ;
WEISSLEDER, R .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1992, 2 (02) :177-181
[5]   EXPERIMENTAL HEPATOCELLULAR-CARCINOMA - MR RECEPTOR IMAGING [J].
REIMER, P ;
WEISSLEDER, R ;
BRADY, TJ ;
YEAGER, AE ;
BALDWIN, BH ;
TENNANT, BC ;
WITTENBERG, J .
RADIOLOGY, 1991, 180 (03) :641-645
[6]   RECEPTOR-DIRECTED CONTRAST AGENTS FOR MR IMAGING - PRECLINICAL EVALUATION WITH AFFINITY ASSAYS [J].
REIMER, P ;
WEISSLEDER, R ;
WITTENBERG, J ;
BRADY, TJ .
RADIOLOGY, 1992, 182 (02) :565-569
[7]   RECEPTOR IMAGING - APPLICATION TO MR IMAGING OF LIVER-CANCER [J].
REIMER, P ;
WEISSLEDER, R ;
LEE, AS ;
WITTENBERG, J ;
BRADY, TJ .
RADIOLOGY, 1990, 177 (03) :729-734
[8]   SUPERPARAMAGNETIC IRON-OXIDE - CLINICAL-APPLICATION AS A CONTRAST AGENT FOR MR IMAGING OF THE LIVER [J].
STARK, DD ;
WEISSLEDER, R ;
ELIZONDO, G ;
HAHN, PF ;
SAINI, S ;
TODD, LE ;
WITTENBERG, J ;
FERRUCCI, JT .
RADIOLOGY, 1988, 168 (02) :297-301
[9]   MR RECEPTOR IMAGING - ULTRASMALL IRON-OXIDE PARTICLES TARGETED TO ASIALOGLYCOPROTEIN RECEPTORS [J].
WEISSLEDER, R ;
REIMER, P ;
LEE, AS ;
WITTENBERG, J ;
BRADY, TJ .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1990, 155 (06) :1161-1167
[10]   ULTRASMALL SUPERPARAMAGNETIC IRON-OXIDE - CHARACTERIZATION OF A NEW CLASS OF CONTRAST AGENTS FOR MR IMAGING [J].
WEISSLEDER, R ;
ELIZONDO, G ;
WITTENBERG, J ;
RABITO, CA ;
BENGELE, HH ;
JOSEPHSON, L .
RADIOLOGY, 1990, 175 (02) :489-493