SEPARATION OF THE 11 PRIORITY POLLUTANT PHENOLS BY CAPILLARY ZONE ELECTROPHORESIS

被引:16
作者
LI, G [1 ]
LOCKE, DC [1 ]
机构
[1] CUNY QUEENS COLL,DEPT CHEM,FLUSHING,NY 11367
来源
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS | 1995年 / 669卷 / 01期
关键词
D O I
10.1016/0378-4347(95)00003-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Capillary zone electrophoresis (CZE) provides highly efficient separation of the eleven US EPA priority pollutant phenols. All of these phenols are completely resolved in fewer than 15 min in a 100 cm x 75 mu m I.D. uncoated fused-silica capillary at 22.5 kV using a pH 9.8 phosphate-borate buffer. Buffer pH is the most critical parameter controlling resolution and separation time. A simple theoretical treatment greatly simplifies the pH optimization procedure. The effects on the separation of buffer concentration, applied voltage, and sample quantity injected were studied. Good calibration data were obtained for phenol concentrations up to 50 mg/l. Limits of detection for all phenols were less than 1 ppm.
引用
收藏
页码:93 / 102
页数:10
相关论文
共 16 条
[1]   TRANSIENT CHANGES OF MOBILE PHASE IN THE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC SEPARATION OF PRIORITY POLLUTANT PHENOLS [J].
ANDRES, MD ;
CANAS, B ;
IZQUIERDO, RC ;
POLO, LM ;
ALARCON, P .
JOURNAL OF CHROMATOGRAPHY, 1990, 507 :399-402
[2]  
BALDWIN D, 1988, CHROMATOGRAPHIA, V26, P176
[3]   DETERMINATION OF PHENOLS IN WATER AND WASTE-WATER BY POSTCOLUMN REACTION DETECTION HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
BIGLEY, FP ;
GROB, RL .
JOURNAL OF CHROMATOGRAPHY, 1985, 350 (02) :407-416
[4]   OPTIMIZATION OF ISOCRATIC MOBILE PHASE-COMPOSITION FOR HPLC ANALYSIS OF 11 SUBSTITUTED PHENOLS [J].
BUSTO, O ;
OLUCHA, JC ;
BORRULL, F .
CHROMATOGRAPHIA, 1991, 32 (11-12) :566-572
[5]   CAPILLARY ZONE ELECTROPHORESIS OF 11 PRIORITY PHENOLS WITH INDIRECT FLUORESCENCE DETECTION [J].
CHAO, YC ;
WHANG, CW .
JOURNAL OF CHROMATOGRAPHY A, 1994, 663 (02) :229-237
[6]   ON-COLUMN SAMPLE CONCENTRATION USING FIELD AMPLIFICATION IN CZE [J].
CHIEN, RL ;
BURGI, DS .
ANALYTICAL CHEMISTRY, 1992, 64 (08) :A489-A496
[7]  
DEAN JA, 1992, LANGES HDB CHEM
[8]   CAPILLARY ZONE ELECTROPHORETIC SEPARATION OF CHLOROPHENOLS IN INDUSTRIAL-WASTE WATER WITH ON-COLUMN ELECTROCHEMICAL DETECTION [J].
GAITONDE, CD ;
PATHAK, PV .
JOURNAL OF CHROMATOGRAPHY, 1990, 514 (02) :389-393
[9]   USE OF POLYMERIC SORBENTS FOR THE OFF-LINE PRECONCENTRATION OF PRIORITY POLLUTANT PHENOLS FROM WATER FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ANALYSIS [J].
GAWDZIK, B ;
GAWDZIK, J ;
CZERWINSKABIL, U .
JOURNAL OF CHROMATOGRAPHY, 1990, 509 (01) :135-140
[10]   OPTIMIZED CAPILLARY ZONE ELECTROPHORETIC SEPARATION OF CHLORINATED PHENOLS [J].
GONNORD, MF ;
COLLET, J .
JOURNAL OF CHROMATOGRAPHY, 1993, 645 (02) :327-336