COMPUTATION OF AORTIC FLOW FROM PRESSURE IN HUMANS USING A NONLINEAR, 3-ELEMENT MODEL

被引:914
作者
WESSELING, KH
JANSEN, JRC
SETTELS, JJ
SCHREUDER, JJ
机构
[1] UNIV LIMBURG,ACAD HOSP,DEPT ANESTHESIOL,6202 AZ MAASTRICHT,NETHERLANDS
[2] ERASMUS UNIV ROTTERDAM,DEPT PULM DIS,3000 DR ROTTERDAM,NETHERLANDS
关键词
AORTIC INPUT IMPEDANCE; NONLINEAR MODEL; TIME-VARYING MODEL; AORTIC ARCTANGENT PRESSURE-AREA RELATIONSHIP; AGE DEPENDENCY; SIMULATION; STROKE VOLUME; CARDIAC OUTPUT;
D O I
10.1152/jappl.1993.74.5.2566
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
We computed aortic flow pulsations from arterial pressure by simulating a nonlinear, time-varying three-element model of aortic input impedance. The model elements represent aortic characteristic impedance, arterial compliance, and systemic vascular resistance. Parameter values for the first two elements were computed from a published, age-dependent, aortic pressure-area relationship (G. J. Langewouters et al. J. Biomech. 17: 425-435, 1984). Peripheral resistance was predicted from mean pressure and model mean flow. Model flow pulsations from aortic pressure showed the visual aspects of an aortic flow curve. For evaluation we compared model mean flow from radial arterial pressure with thermodilution cardiac output estimations, 76 times, in eight open heart surgical patients. The pooled mean difference was +7%, the SD 22%. After using one comparison per patient to calibrate the model, however, we followed quantitative changes in cardiac output that occurred either during changes in the state of the patient or subsequent to vasoactive drugs. The mean deviation from thermodilution cardiac output was +2%, the SD 8%. Given these small errors the method could monitor cardiac output continuously.
引用
收藏
页码:2566 / 2573
页数:8
相关论文
共 20 条
[11]  
Nichols WV, 1990, MCDONALDS BLOOD FLOW
[12]   RADIAL ARTERY-TO-AORTA PRESSURE DIFFERENCE AFTER DISCONTINUATION OF CARDIOPULMONARY BYPASS [J].
PAUCA, AL ;
HUDSPETH, AS ;
WALLENHAUPT, SL ;
TUCKER, WY ;
KON, ND ;
MILLS, SA ;
CORDELL, AR .
ANESTHESIOLOGY, 1989, 70 (06) :935-941
[13]  
PURSCHKE R, 1974, ANAESTHESIST, V23, P525
[14]  
SMITH NT, 1974, P SAN DIEGO BIOMED S, V13, P113
[15]   INITIAL BLOOD-PRESSURE FALL ON STAND UP AND EXERCISE EXPLAINED BY CHANGES IN TOTAL PERIPHERAL RESISTANCE [J].
SPRANGERS, RLH ;
WESSELING, KH ;
IMHOLZ, ALT ;
IMHOLZ, BPM ;
WIELING, W .
JOURNAL OF APPLIED PHYSIOLOGY, 1991, 70 (02) :523-530
[16]   BEAT-TO-BEAT ESTIMATION OF PERIPHERAL RESISTANCE AND ARTERIAL COMPLIANCE DURING PRESSURE TRANSIENTS [J].
TOOROP, GP ;
WESTERHOF, N ;
ELZINGA, G .
AMERICAN JOURNAL OF PHYSIOLOGY, 1987, 252 (06) :H1275-H1283
[17]   QUANTITATION OF BEAT-TO-BEAT CHANGES IN STROKE VOLUME FROM THE AORTIC PULSE CONTOUR IN MAN [J].
WARNER, HR ;
SWAN, HJC ;
CONNOLLY, DC ;
TOMPKINS, RG ;
WOOD, EH .
JOURNAL OF APPLIED PHYSIOLOGY, 1953, 5 (09) :495-507
[18]  
Wesseling KH, 1983, ADV CARDIOVASC PHYS, V5, P16
[19]  
WESSLING KH, 1982, MONITORING KONZEPTE, P8
[20]  
WETTERER E, 1968, GRUNDLAGEN DYNAMIK A