RAPID DETECTION OF PARACETAMOL USING A DISPOSABLE, SURFACE-MODIFIED SCREEN-PRINTED CARBON ELECTRODE

被引:39
作者
GILMARTIN, MAT [1 ]
HART, JP [1 ]
机构
[1] UNIV W ENGLAND,FAC SCI APPL,BRISTOL BS16 1QY,AVON,ENGLAND
关键词
AMPEROMETRY; PARACETAMOL; SCREEN PRINTING; PERMSELECTIVITY; URINE ANALYSIS;
D O I
10.1039/an9941902431
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A method for the rapid and simple determination of paracetamol in urine is described. The transducer is a reagentless, amperometric sensor that was developed through the combined use of screen-printing and permselective membrane technologies. The sensor operates selectively by means of an anti-interference barrier, cellulose acetate, which is drop-coated directly on to the screen-printed carbon electrodes. The disposable, amperometric sensor require no further modification procedures to enhance selectivity, i.e., no enzymes are involved, and hence their fabrication is simple and extremely economical. Gi,en the rapid response times, 13 x 10(-6) mol dm(-3) limit of detection and wide functional range, linear up to 2 x 10(-3) mol dm(-3), they represent an attractive alternative for paracetamol monitoring. The surface-modified strips were applied to the detection of paracetamol in urine,correlating well with a standard enzyme-colour reagent kit.
引用
收藏
页码:2431 / 2437
页数:7
相关论文
共 33 条
[21]  
MATTHEWS DR, 1987, LANCET, V1, P778
[22]  
MATTHEWS DR, 1987, LANCET, V1, P8356
[23]   SIMULTANEOUS HIGH-PRESSURE LIQUID-CHROMATOGRAPHIC DETERMINATION OF ACETAMINOPHEN, GUAIFENESIN, AND DEXTROMETHORPHAN HYDROBROMIDE IN COUGH SYRUP [J].
MCSHARRY, WO ;
SAVAGE, IVE .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1980, 69 (02) :212-214
[24]  
MINER DJ, 1981, ANAL CHEM, V53, P2258, DOI 10.1021/ac00237a029
[25]  
MITCHELL JR, 1974, CLIN PHARMACOL THER, V16, P676
[26]   DETERMINATION OF ACETAMINOPHEN IN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION [J].
MUNSON, JW ;
WEIERSTALL, R ;
KOSTENBAUDER, HB .
JOURNAL OF CHROMATOGRAPHY, 1978, 145 (02) :328-331
[27]   AMPEROMETRIC ASSAY OF GLUCOSE AND LACTIC-ACID BY FLOW-INJECTION ANALYSIS [J].
PETERSSON, BA .
ANALYTICA CHIMICA ACTA, 1988, 209 (1-2) :231-237
[28]   PARACETAMOL OVERDOSAGE - PHARMACOLOGICAL CONSIDERATIONS AND CLINICAL MANAGEMENT [J].
PRESCOTT, LF .
DRUGS, 1983, 25 (03) :290-314
[29]   EFFICACY OF ORAL N-ACETYLCYSTEINE IN THE TREATMENT OF ACETAMINOPHEN OVERDOSE - ANALYSIS OF THE NATIONAL MULTICENTER STUDY (1976 TO 1985) [J].
SMILKSTEIN, MJ ;
KNAPP, GL ;
KULIG, KW ;
RUMACK, BH .
NEW ENGLAND JOURNAL OF MEDICINE, 1988, 319 (24) :1557-1562
[30]   LATE TREATMENT OF PARACETAMOL POISONING WITH MERCAPTAMINE [J].
SMITH, JM ;
ROBERTS, WO ;
HALL, SM ;
WHITE, TA ;
GILBERTSON, AA .
BRITISH MEDICAL JOURNAL, 1978, 1 (6109) :331-333