EMERGENCY ENDOLUMINAL STENTING FOR ABRUPT VESSEL CLOSURE FOLLOWING CORONARY ANGIOPLASTY - A RANDOMIZED COMPARISON OF THE WIKTOR AND PALMAZ-SCHATZ STENTS

被引:20
作者
GOY, JJ
EECKHOUT, E
STAUFFER, JC
VOGT, P
KAPPENBERGER, L
机构
[1] Cardiology Division, Centre Hospitalier Universitaire Vaudois, Lausanne
来源
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS | 1995年 / 34卷 / 02期
关键词
STENTS; CORONARY ANGIOPLASTY; TRANSLUMINAL;
D O I
10.1002/ccd.1810340410
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
In order to compare the efficacy of two different stent types in case of bailout stenting, 65 patients, with abrupt or threatened vessel closure following coronary angioplasty, were randomly assigned to either Wiktor (Medtronic Inc., Minneapolis, MN, 33 patients) or Palmaz-Schatz (Johnson & Johnson Interventional, Warren, NJ, 32 patients) stent implantation. Stenting was technically feasible in all except one patient and immediately successful in reverting ischemia and vessel closure in 60 patients (92%). At hospital discharge, complication rates were comparable: early vessel closure, 18% (Wiktor) versus 13% (Palmaz-Schatz) (P = 0.53); any clinical event (such as death, myocardial infarction, and surgical revascularization): 18% (Wiktor) versus 22% (Palmaz-Schatz) (P = 0.71). At 6 months follow-up, these complication rates remained equal: restenosis, 38% (Wiktor) versus 27% (Palmaz-Schatz) (P=0.42); any clinical and angiographic (vessel closure and restenosis) event: 45% (Wiktor) and 41% (Palmaz-Schatz) (P = 0.69). Baseline, direct post-procedural, and follow-up quantitative coronary analysis data were similar, with, however, an exception for the postprocedural residual stenosis [28% (24-32%) (Wiktor) and 21% (18-23%) (Palmaz-Schatz] (means and 95% confidence intervals). In conclusion, despite a discrete postprocedural angiographic benefit observed with the Palmaz-Schatz stent, the long-term clinical and angiographic outcome is similar in both treatment groups. The choice whether to implant a Wiktor or Palmaz-Schatz stent may probably be left to the discretion of the operator and his experience with one particular device. (C) 1995 Wiley-Liss, Inc.
引用
收藏
页码:128 / 132
页数:5
相关论文
共 14 条
[1]   ACUTE CORONARY-ARTERY OCCLUSION DURING AND AFTER PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY - FREQUENCY, PREDICTION, CLINICAL COURSE, MANAGEMENT, AND FOLLOW-UP [J].
DEFEYTER, PJ ;
VANDENBRAND, M ;
JAARMAN, G ;
VANDOMBURG, R ;
SERRUYS, PW ;
SURYAPRANATA, H .
CIRCULATION, 1991, 83 (03) :927-936
[2]   EMERGENCY STENTING FOR REFRACTORY ACUTE CORONARY-ARTERY OCCLUSION DURING CORONARY ANGIOPLASTY [J].
DEFEYTER, PJ ;
DESCHEERDER, I ;
VANDENBRAND, M ;
LAARMAN, GJ ;
SURYAPRANATA, H ;
SERRUYS, PW .
AMERICAN JOURNAL OF CARDIOLOGY, 1990, 66 (15) :1147-1150
[3]   RESULTS OF INTRACORONARY STENTS FOR MANAGEMENT OF CORONARY DISSECTION AFTER BALLOON ANGIOPLASTY [J].
HAUDE, M ;
ERBEL, R ;
STRAUB, U ;
DIETZ, U ;
SCHATZ, R ;
MEYER, J .
AMERICAN JOURNAL OF CARDIOLOGY, 1991, 67 (08) :691-696
[4]   OUTCOME AFTER PROLONGED BALLOON INFLATIONS OF GREATER-THAN-20 MINUTES FOR INITIALLY UNSUCCESSFUL PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY [J].
JACKMAN, JD ;
ZIDAR, JP ;
TCHENG, JE ;
OVERMAN, AB ;
PHILLIPS, HR ;
STACK, RS .
AMERICAN JOURNAL OF CARDIOLOGY, 1992, 69 (17) :1417-1421
[5]  
KLEPZIG H, 1991, EUR HEART J, V12, P946
[6]   OUTCOME AFTER MAJOR DISSECTION DURING CORONARY ANGIOPLASTY USING THE PERFUSION BALLOON CATHETER [J].
LEITSCHUH, ML ;
MILLS, RM ;
JACOBS, AK ;
RUOCCO, NA ;
LAROSA, D ;
FAXON, DP .
AMERICAN JOURNAL OF CARDIOLOGY, 1991, 67 (13) :1056-1060
[7]  
MOVSOWITZ H, 1993, CIRCULATION, V88, P601
[8]  
POPE DL, 1984, COMP CARDIOL, V4, P71
[9]   STRECKER STENT AS A BAILOUT DEVICE FOLLOWING PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY [J].
REIFART, N ;
LANGER, A ;
STORGER, H ;
SCHWARZ, F ;
PREUSLER, W ;
HOFMANN, M .
JOURNAL OF INTERVENTIONAL CARDIOLOGY, 1992, 5 (02) :79-83
[10]   INTRACORONARY STENTING FOR ACUTE AND THREATENED CLOSURE COMPLICATING PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY [J].
ROUBIN, GS ;
CANNON, AD ;
AGRAWAL, SK ;
MACANDER, PJ ;
DEAN, LS ;
BAXLEY, WA ;
BRELAND, J .
CIRCULATION, 1992, 85 (03) :916-927