IMAGING MODES FOR BILATERAL CONFOCAL SCANNING MICROSCOPY

被引:17
作者
BRAKENHOFF, GJ
VISSCHER, K
机构
[1] Section of Molecular Cytology, Department of Molecular Cell Biology, University of Amsterdam, Amsterdam, 1018 TV
来源
JOURNAL OF MICROSCOPY-OXFORD | 1993年 / 171卷
关键词
CONFOCAL; BILATERAL; CCD; RATIO IMAGING; FLUORESCENCE MICROSCOPY; REFLECTION INTERFERENCE MICROSCOPY;
D O I
10.1111/j.1365-2818.1993.tb03355.x
中图分类号
TH742 [显微镜];
学科分类号
摘要
The bilateral scanning approach to confocal microscopy is characterized by the direct generation of the image on a two-dimensional (2-D) detector. This detector can be a photographic plate, a CCD detector or the human eye, the human eye permitting direct visualization of the confocal image. Unlike Nipkow-type systems, laser light sources can be used for excitation. A design called a carousel has been developed, in which the bilateral confocal scan capability can be added to an existing microscope so that rapid exchange and comparison between confocal and non-confocal imaging conditions is possible. The design permits independent adjustment of confocal sectioning properties with lateral resolutions better than, or, in the worst case equivalent to, those available in conventional microscopy. The carousel can be considered as a stationary optical path in which certain imaging conditions, such as confocality, are defined and operate on part of the imaging field. The action of the bilateral scan mirror then extends this image condition over the whole field. A number of optical arrangements for the carousel are presented which realize various forms of confocal fluorescence and reflection imaging, with point, multiple point or slit confocal detection arrangements. Through the addition of active elements to the carousel direct stereoscopic, ratio, time-resolved and other types of imaging can be achieved, with direct image formation on a CCD, eye or other 2-D detectors without the need to modify the host microscope. Depending on the photon flux available, these imaging modes can run in real-time or can use a cooled CCD at (very) low light level for image integration over an extended period.
引用
收藏
页码:17 / 26
页数:10
相关论文
共 16 条
  • [1] BRAKENHOFF GJ, 1989, P SOC PHOTO-OPT INS, V1139, P117, DOI 10.1117/12.961783
  • [2] CONFOCAL IMAGING WITH BILATERAL SCANNING AND ARRAY DETECTORS
    BRAKENHOFF, GJ
    VISSCHER, K
    [J]. JOURNAL OF MICROSCOPY-OXFORD, 1992, 165 : 139 - 146
  • [3] JOHNSON CB, 1992, P SPIE, V1655, P1
  • [4] SURFACE PROFILING WITH SCANNING OPTICAL MICROSCOPES USING 2-MODE OPTICAL FIBERS
    JUSKAITIS, R
    WILSON, T
    [J]. APPLIED OPTICS, 1992, 31 (22): : 4569 - 4574
  • [5] KIMMA S, 1991, APPL OPTICS, V30, P2143
  • [6] KOESTER CJ, 1980, APPL OPTICS, V19, P1949
  • [7] KOESTER CJ, 1990, HDB BIOL CONFOCAL MI, P207
  • [8] TANDEM-SCANNING REFLECTED-LIGHT MICROSCOPE
    PETRAN, M
    HADRAVSKY, M
    EGGER, MD
    GALAMBOS, R
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1968, 58 (05) : 661 - +
  • [9] SIGNAL-TO-NOISE RATIO IN CONFOCAL MICROSCOPE SYSTEMS
    SHEPPARD, CJR
    GU, M
    ROY, M
    [J]. JOURNAL OF MICROSCOPY-OXFORD, 1992, 168 : 209 - 218
  • [10] TSIEN RY, 1989, FLUORESCENCE MICROSC, P127