CONTINUOUS AUTOMATED-DETERMINATION OF ATMOSPHERIC FORMALDEHYDE AT THE PARTS-PER-TRILLION LEVEL

被引:83
作者
FAN, Q [1 ]
DASGUPTA, PK [1 ]
机构
[1] TEXAS TECH UNIV,DEPT CHEM & BIOCHEM,LUBBOCK,TX 79409
关键词
D O I
10.1021/ac00076a021
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
1,3-Cyclohexanedione was used for automated near real-time fluorometric determination of atmospheric formaldehyde. Although previous literature reports indicate this reagent to be nonselective, adaptation of a fast flow injection technique that does not rely on the completion of the reaction provided a method with a selectivity factor of >300 for HCHO over its nearest congener, CH3CHO. The system was optimized with respect to the reagent and scrubber liquid composition, reaction temperature, and pH. The limit of detection (LOD) in the aqueous phase is similar to 6 nM (180 ng/L) HCHO for a 45-mu L, sample (270 fmol) with the linear dynamic range spanning >3 orders of magnitude, up to at least 14 mu M. The mean relative standard deviation in the 14 nM-14 mu M range is 3%. Gas-phase measurements utilized a Nafion 811 hydrophilic membrane tube based diffusion scrubber with ii ater as the scrubbing liquid carrier. At a sampling rate of 1.4 L/min, the LOD for gas-phase HCHO is 9 pptrv. The mean rsd in the 0.07-110 ppbv range is 1.5%.
引用
收藏
页码:551 / 556
页数:6
相关论文
共 31 条
[1]   DETERMINATION OF FORMALDEHYDE IN GAS MIXTURES BY CHROMOTROPIC ACID METHOD [J].
ALTSHULLER, A ;
MILLER, DL ;
SLEVA, SF .
ANALYTICAL CHEMISTRY, 1961, 33 (04) :621-+
[2]   2,4-DINITROPHENYLHYDRAZINE-COATED SILICA-GEL CARTRIDGE METHOD FOR DETERMINATION OF FORMALDEHYDE IN AIR - IDENTIFICATION OF AN OZONE INTERFERENCE [J].
ARNTS, RR ;
TEJADA, SB .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1989, 23 (11) :1428-1430
[3]   SIMULTANEOUS ABSOLUTE MEASUREMENTS OF GASEOUS NITROGEN SPECIES IN URBAN AMBIENT AIR BY LONG PATHLENGTH INFRARED AND ULTRAVIOLET VISIBLE SPECTROSCOPY [J].
BIERMANN, HW ;
TUAZON, EC ;
WINER, AM ;
WALLINGTON, TJ ;
PITTS, JN .
ATMOSPHERIC ENVIRONMENT, 1988, 22 (08) :1545-1554
[4]   EVALUATION OF A PASSIVE SAMPLER FOR AIRBORNE FORMALDEHYDE [J].
BINDING, N ;
WITTING, U .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1991, 339 (04) :218-222
[5]  
CHANSA MK, 1991, TALANTA, V38, P1381
[6]   AVERAGE CONCENTRATIONS OF OH IN TROPOSPHERE, AND BUDGETS OF CH4 CO H-2 + CH3CCL3 [J].
CRUTZEN, PJ ;
FISHMAN, J .
GEOPHYSICAL RESEARCH LETTERS, 1977, 4 (08) :321-324
[7]   DETERMINATION OF FORMALDEHYDE BY HPLC AS THE DNPH DERIVATIVE FOLLOWING HIGH-VOLUME AIR SAMPLING ONTO BISULFITE-COATED CELLULOSE FILTERS [J].
DEANDRADE, JB ;
TANNER, RL .
ATMOSPHERIC ENVIRONMENT PART A-GENERAL TOPICS, 1992, 26 (05) :819-825
[8]  
EHHALT DH, 1981, ENV SIC TECHNOL, V15, P819
[9]   SPECTROMETRIC ASSAY OF ALDEHYDES AS 6-MERCAPTO-3-SUBSTITUTED-S-TRIAZOLO(4,3-B)-S-TETRAZINES [J].
JACOBSEN, NW ;
DICKINSON, RG .
ANALYTICAL CHEMISTRY, 1974, 46 (02) :298-299
[10]   METHOD FOR THE DETERMINATION OF SOME SOLUBLE ATMOSPHERIC CARBONYL-COMPOUNDS [J].
LEE, YN ;
ZHOU, XL .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1993, 27 (04) :749-756