APPLICATION OF THE FAST-EVAPORATION SAMPLE PREPARATION METHOD FOR IMPROVING QUANTIFICATION OF ANGIOTENSIN-II BY MATRIX-ASSISTED LASER-DESORPTION IONIZATION

被引:98
作者
NICOLA, AJ
GUSEV, AI
PROCTOR, A
JACKSON, EK
HERCULES, DM
机构
[1] UNIV PITTSBURGH,DEPT CHEM,PITTSBURGH,PA 15260
[2] UNIV PITTSBURGH,DEPT CLIN PHARMACOL,PITTSBURGH,PA 15260
关键词
D O I
10.1002/rcm.1290091216
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The fast-evaporation method of sample preparation has been applied for quantitative analysis using matrix-assisted laser desorption/ionization (MALDI) mass spectrometry. An instrumental protocol focusing on improvement of shot-to-shot repeatability and compensation for signal degradation has been developed for quantification of angiotensin II using the fast-evaporation technique and an internal standard. The fast-evaporation method was compared to the standard method of sample preparation (using a multicomponent matrix) in the quantitative analysis of angiotensin II, and found to be superior in several respects, Improvement In sample homogeneity using the Past-evaporation method enhanced both point-to-point repeatibility and sample-to-sample reproducibility. The relative standard deviations of the analyte/internal standard ratios (point RSD) were decreased by a factor of three compared to those obtained using the multicomponent matrix method, The average point RSD was found to be ca. 5% for the fast-evaporation technique. Two internal standards were evaluated for quantification of angiotensin II. The better one, 1-SAR-8-Ile angiotensin II, yielded a relative standard deviation of the standard curve slope of ca. 2.2% over two orders of magnitude of concentration (45 nM to 3000 nM), an improvement by a factor of two over the standard preparation method. Renal microdialysate samples, spiked with angiotensin II and the internal standard 1-SAR-8-Ile angiotensin II, were also analyzed using the fast-evaporation technique. The detection limit was calculated to be in the high attomole range (675 amol). Furthermore, the accuracy for a single determination of angiotensin II concentration in these samples was found to be 13.9% with a relative error of 8.19%.
引用
收藏
页码:1164 / 1171
页数:8
相关论文
共 23 条
[1]   ESTIMATION OF RENAL INTERSTITIAL ADENOSINE AND PURINE METABOLITES BY MICRODIALYSIS [J].
BARANOWSKI, RL ;
WESTENFELDER, C .
AMERICAN JOURNAL OF PHYSIOLOGY, 1994, 267 (01) :F174-F182
[2]   TRYPTIC MAPPING OF RECOMBINANT PROTEINS BY MATRIX-ASSISTED LASER-DESORPTION IONIZATION MASS-SPECTROMETRY [J].
BILLECI, TM ;
STULTS, JT .
ANALYTICAL CHEMISTRY, 1993, 65 (13) :1709-1716
[3]  
DEBOOR C, 1978, PRACTICAL GUIDE SPLI, P235
[4]   QUANTITATIVE-ANALYSIS OF LOW-MOLECULAR-WEIGHT COMPOUNDS OF BIOLOGICAL INTEREST BY MATRIX-ASSISTED LASER-DESORPTION IONIZATION [J].
DUNCAN, MW ;
MATANOVIC, G ;
CERPAPOLJAK, A .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1993, 7 (12) :1090-1094
[5]   QUANTITATIVE-DETERMINATION OF BETA(1-2) CYCLIC GLUCANS BY MATRIX-ASSISTED LASER-DESORPTION MASS-SPECTROMETRY [J].
GAROZZO, D ;
SPINA, E ;
STURIALE, L ;
MONTAUDO, G ;
RIZZO, R .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1994, 8 (05) :358-360
[6]   IMPROVEMENT OF SIGNAL REPRODUCIBILITY AND MATRIX/COMATRIX EFFECTS IN MALDI ANALYSIS [J].
GUSEV, AI ;
WILKINSON, WR ;
PROCTOR, A ;
HERCULES, DM .
ANALYTICAL CHEMISTRY, 1995, 67 (06) :1034-1041
[7]  
GUSEV AI, 1993, APPL SPECTROSC, V47, P8
[8]  
GUSEV AI, UNPUB FRESENIUS J AN
[9]   QUANTITATIVE ASPECTS OF THE MATRIX-ASSISTED LASER-DESORPTION MASS-SPECTROMETRY OF COMPLEX OLIGOSACCHARIDES [J].
HARVEY, DJ .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1993, 7 (07) :614-619
[10]  
KARAS M, 1992, 40TH P ASMS C MASS S, P368