APPLICATION OF THE FAST-EVAPORATION SAMPLE PREPARATION METHOD FOR IMPROVING QUANTIFICATION OF ANGIOTENSIN-II BY MATRIX-ASSISTED LASER-DESORPTION IONIZATION

被引:98
作者
NICOLA, AJ
GUSEV, AI
PROCTOR, A
JACKSON, EK
HERCULES, DM
机构
[1] UNIV PITTSBURGH,DEPT CHEM,PITTSBURGH,PA 15260
[2] UNIV PITTSBURGH,DEPT CLIN PHARMACOL,PITTSBURGH,PA 15260
关键词
D O I
10.1002/rcm.1290091216
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The fast-evaporation method of sample preparation has been applied for quantitative analysis using matrix-assisted laser desorption/ionization (MALDI) mass spectrometry. An instrumental protocol focusing on improvement of shot-to-shot repeatability and compensation for signal degradation has been developed for quantification of angiotensin II using the fast-evaporation technique and an internal standard. The fast-evaporation method was compared to the standard method of sample preparation (using a multicomponent matrix) in the quantitative analysis of angiotensin II, and found to be superior in several respects, Improvement In sample homogeneity using the Past-evaporation method enhanced both point-to-point repeatibility and sample-to-sample reproducibility. The relative standard deviations of the analyte/internal standard ratios (point RSD) were decreased by a factor of three compared to those obtained using the multicomponent matrix method, The average point RSD was found to be ca. 5% for the fast-evaporation technique. Two internal standards were evaluated for quantification of angiotensin II. The better one, 1-SAR-8-Ile angiotensin II, yielded a relative standard deviation of the standard curve slope of ca. 2.2% over two orders of magnitude of concentration (45 nM to 3000 nM), an improvement by a factor of two over the standard preparation method. Renal microdialysate samples, spiked with angiotensin II and the internal standard 1-SAR-8-Ile angiotensin II, were also analyzed using the fast-evaporation technique. The detection limit was calculated to be in the high attomole range (675 amol). Furthermore, the accuracy for a single determination of angiotensin II concentration in these samples was found to be 13.9% with a relative error of 8.19%.
引用
收藏
页码:1164 / 1171
页数:8
相关论文
共 23 条
[21]   IMPROVED RESOLUTION AND VERY HIGH-SENSITIVITY IN MALDI TOF OF MATRIX SURFACES MADE BY FAST EVAPORATION [J].
VORM, O ;
ROEPSTORFF, P ;
MANN, M .
ANALYTICAL CHEMISTRY, 1994, 66 (19) :3281-3287
[22]   IMPROVED MASS ACCURACY IN MATRIX-ASSISTED LASER DESORPTION/IONIZATION TIME-OF-FLIGHT MASS-SPECTROMETRY OF PEPTIDES [J].
VORM, O ;
MANN, M .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1994, 5 (11) :955-958
[23]  
WEINBERG SR, 1992, SEP KYOT 92 2NT C BI