GRAPHICAL ANALYSIS OF MR FEATURE SPACE FOR MEASUREMENT OF CSF, GRAY-MATTER, AND WHITE-MATTER VOLUMES

被引:34
作者
BONAR, DC
SCHAPER, KA
ANDERSON, JR
ROTTENBERG, DA
STROTHER, SC
机构
[1] UNIV MINNESOTA,DEPT NEUROL,MINNEAPOLIS,MN 55455
[2] UNIV MINNESOTA,DEPT RADIOL,MINNEAPOLIS,MN 55455
关键词
MAGNETIC RESONANCE IMAGING; TECHNIQUES; BRAIN; WHITE GRAY MATTER; CEREBROSPINAL FLUID; VOLUME DETERMINATION;
D O I
10.1097/00004728-199305000-00024
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The problem of volume averaging in quantitating CSF, gray-matter, and white-matter fractions in the brain is solved using a three-compartment model and a simple graphical analysis of a multispectral MR feature space. Compartmentalization is achieved without the ambiguities of thresholding techniques or the need to assume that the underlying pixel probability distributions have a particular form. A 2D feature space is formed by double SE (proton density- and T2-weighted) MR data with image nonuniformity removed by a novel technique in which the brain itself serves as a uniformity reference. Compartments other than the basic three were rejected by the tailoring of limits in feature space. Phantom scans substantiate this approach, and the importance of the careful selection and standardization of pure tissue reference signals is demonstrated. Compartmental profiles from standardized subvolumes of three normal brains, based on a 3D (Talairach) coordinate system, demonstrate slice-by-slice detail; longitudinal studies confirm reproducibility. Compartmentalization may be described graphically and algebraically, complementing data displays in feature space and images of compartmentalized brain scans. These studies anticipate the application of our compartmentalization technique to patients with neurological disorders.
引用
收藏
页码:461 / 470
页数:10
相关论文
共 16 条
  • [1] Blackledge J., 1989, QUANTITATIVE COHEREN
  • [2] CHANDRA R, 1990, SPIE BIOMED IMAGE P, V1245, P124
  • [3] PARTIAL VOLUME TISSUE CLASSIFICATION OF MULTICHANNEL MAGNETIC-RESONANCE IMAGES - A MIXEL MODEL
    CHOI, HS
    HAYNOR, DR
    KIM, YM
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1991, 10 (03) : 395 - 407
  • [4] A QUANTITATIVE INDEX OF VENTRICULAR AND EXTRAVENTRICULAR INTRACRANIAL CSF VOLUMES USING MR IMAGING
    CONDON, BR
    PATTERSON, J
    WYPER, D
    HADLEY, DM
    TEASDALE, G
    GRANT, R
    JENKINS, A
    MACPHERSON, P
    ROWAN, J
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1986, 10 (05) : 784 - 792
  • [5] USER-FRIENDLY METHOD FOR RAPID BRAIN AND CSF VOLUME CALCULATION USING TRANSAXIAL MRI IMAGES
    HARRIS, GJ
    RHEW, EH
    NOGA, T
    PEARLSON, GD
    [J]. PSYCHIATRY RESEARCH-NEUROIMAGING, 1991, 40 (01) : 61 - 68
  • [6] MEASUREMENT OF BRAIN COMPARTMENT VOLUMES IN MR USING VOXEL COMPOSITION CALCULATIONS
    HILLMAN, GR
    KENT, TA
    KAYE, A
    BRUNDER, DG
    TAGARE, H
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1991, 15 (04) : 640 - 646
  • [7] METHODS FOR MEASURING BRAIN MORPHOLOGIC FEATURES ON MAGNETIC-RESONANCE IMAGES - VALIDATION AND NORMAL AGING
    JERNIGAN, TL
    PRESS, GA
    HESSELINK, JR
    [J]. ARCHIVES OF NEUROLOGY, 1990, 47 (01) : 27 - 32
  • [8] A NEW HEADHOLDER FOR PET, CT, AND NMR IMAGING
    KEARFOTT, KJ
    ROTTENBERG, DA
    KNOWLES, RJR
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1984, 8 (06) : 1217 - 1220
  • [9] ANALYSIS OF BRAIN AND CEREBROSPINAL-FLUID VOLUMES WITH MR IMAGING .1. METHODS, RELIABILITY, AND VALIDATION
    KOHN, MI
    TANNA, NK
    HERMAN, GT
    RESNICK, SM
    MOZLEY, PD
    GUR, RE
    ALAVI, A
    ZIMMERMAN, RA
    GUR, RC
    [J]. RADIOLOGY, 1991, 178 (01) : 115 - 122
  • [10] SEGMENTATION OF MR BRAIN IMAGES INTO CEREBROSPINAL-FLUID SPACES, WHITE AND GRAY-MATTER
    LIM, KO
    PFEFFERBAUM, A
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1989, 13 (04) : 588 - 593