摘要
该文报道了一种用于检测有机磷农药的安培生物传感器,将钴(Ⅱ)-4,4',4'',4'''四氨基酞菁(CoTAPc)单体电聚合到一支玻碳电极上作为硫代胆碱电化学氧化的电催化剂,通过交联的方法将乙酰胆碱酯酶(AChE)固定在醋酸纤维膜上,再将该酶膜固定于聚四氨基钴酞菁(p-CoTAPc)修饰电极表面。采用10min 的温育时间,百分抑制率与对硫磷或乐果浓度的对数值都在1.0×10-9~1.0×10-6mol/L 浓度范围内呈线性关系,检测限分别可达7.0×10-10mol/L 和2.6×10-10mol/L。农药对 AChE 的抑制作用产生后,用2-吡啶醛肟甲基氯化物(2-PAM)可以有效地使酶膜再生活化。
引用
收藏
页码:52 / 56
页数:5
相关论文
共 9 条
[1]  
Determination of Pesticides Using Electrochemical Enzymatic Biosensors[J] . MarekTrojanowicz.Electroanalysis . 2002 (19‐)
[2]   Oxidation of organophosphorus pesticides for the sensitive detection by a cholinesterase-based biosensor [J].
Lee, HS ;
Kim, YA ;
Cho, YA ;
Lee, YT .
CHEMOSPHERE, 2002, 46 (04) :571-576
[3]  
Development of a quantitative relationship between inhibition percentage and both incubation time and inhibitor concentration for inhibition biosensors—theoretical and practical considerations[J] . S. Zhang,H. Zhao,R. John.Biosensors and Bioelectronics . 2001 (9)
[4]  
Biosensors for direct determination of organophosphate pesticides[J] . Ashok Mulchandani,Wilfred Chen,Priti Mulchandani,Joseph Wang,Kim R Rogers.Biosensors and Bioelectronics . 2001 (4)
[5]  
Materials and techniques for electrochemical biosensor design and construction[J] . S Zhang,G Wright,Y Yang.Biosensors and Bioelectronics . 2000 (5)
[6]   Multichannel amperometric detection system for liquid chromatography to assay the thiols in human whole blood using the platinum microelectrodes chemically modified by copper tetraaminophthalocyanine [J].
Zhang, S ;
Sun, WL ;
Xian, YZ ;
Zhang, W ;
Jin, LT ;
Yamamoto, K ;
Tao, SG ;
Jin, JY .
ANALYTICA CHIMICA ACTA, 1999, 399 (03) :213-221
[7]   Determination of nitric oxide with ultramicrosensors based on electropolymerized films of metal tetraaminophthalocyanines [J].
Jin, JY ;
Miwa, T ;
Mao, LQ ;
Tu, HP ;
Jin, LT .
TALANTA, 1999, 48 (05) :1005-1011
[8]  
Voltammetric behaviour of dopamine at nickel phthalocyanine polymer modified electrodes and analytical applications[J] . Tian-Fang Kang,Guo-Li Shen,Ru-Qin Yu.Analytica Chimica Acta . 1997 (1)
[9]  
Determination of organophosphorus and carbamate pesticides using a biosensor based on a polishable, 7,7,8,8-tetracyanoquino-dimethane-modified, graphite—epoxy biocomposite[J] . Daniel Martorell,Francisco Céspedes,Esteve Martínez-Fàbregas,Salvador Alegret.Analytica Chimica Acta . 1997 (3)