基于纳米金自组装膜固定辣根过氧化物酶的生物传感研究

被引:4
作者
左国防
袁焜
潘素娟
机构
[1] 甘肃省高校新型分子材料设计与功能省级重点实验室
关键词
自组装膜; 纳米技术; 电子传递; 过氧化氢; 电化学生物传感;
D O I
暂无
中图分类号
TP212.3 [生物传感器、医学传感器];
学科分类号
摘要
将辣根过氧化物酶(HRP)通过纳米技术和自组装技术固定于电极表面,制得了酶修饰电极。纳米金与HRP形成了静电复合物并高效地保持了HRP的生物活性,以对苯二酚作为电子媒介体,差示脉冲伏安法(DPV)研究生物酶电极测定H2O2的线性范围为5.0×10-6~1.0×10-3 mol/L,检测限为2.5×10-6 mol/L,线性方程为△I=0.34765+4.05553CH2O2(mM)。酶电极的表观米氏常数(Kmapp)为0.0675 mmol/L。实验同时证明该生物酶电极具有良好的稳定性和使用寿命。
引用
收藏
页码:84 / 89
页数:6
相关论文
共 8 条
[1]   A novel hydrogen peroxide biosensor based on the immobilization of horseradish peroxidase onto Au-modified titanium dioxide nanotube arrays [J].
Kafi, A. K. M. ;
Wu, Guosheng ;
Chen, Aicheng .
BIOSENSORS & BIOELECTRONICS, 2008, 24 (04) :566-571
[2]  
Horseradish and soybean peroxidases: comparable tools for alternative niches?[J] . Barry J. Ryan,Neil Carolan,Ciarán ó’Fágáin.Trends in Biotechnology . 2006 (8)
[3]   Renewable reagentless hydrogen peroxide sensor based on direct electron transfer of horseradish peroxidase immobilized on colloidal gold-modified electrode [J].
Liu, SQ ;
Ju, HX .
ANALYTICAL BIOCHEMISTRY, 2002, 307 (01) :110-116
[4]   Direct electrochemistry and electrocatalysis with horseradish peroxidase in Eastman AQ films [J].
Huang, R ;
Hu, NF .
BIOELECTROCHEMISTRY, 2001, 54 (01) :75-81
[5]   Hydrogen peroxide sensor based on horseradish peroxidase-labeled Au colloids immobilized on gold electrode surface by cysteamine monolayer [J].
Xiao, Y ;
Ju, HX ;
Chen, HY .
ANALYTICA CHIMICA ACTA, 1999, 391 (01) :73-82
[6]  
Horseradish peroxidase enzyme immobilized on titanium( IV ) oxide coated cellulose microfibers: study of the enzymatic activity by flow injection system[J] . Lindomar R.D. da Silva,Yoshitaka Gushikem,Lauro T. Kubota.Colloids and Surfaces B: Biointerfaces . 1996 (4)
[7]  
Silica sol-gel immobilized amperometric biosensor for hydrogen peroxide[J] . Juan Li,Swee Ngin Tan,Hailin Ge.Analytica Chimica Acta . 1996 (1)
[8]  
Characterization of regenerated silk fibroin membrane for immobilizing peroxidase and construction of an amperometric hydrogen peroxide sensor employing phenazine methosulphate as electron shuttle[J] . Jianghong Qian,Yongcheng Liu,Haiying Liu,Tongyin Yu,Jiaqi Deng.Journal of Electroanalytical Chemistry . 1995 (1)