A novel hydrogen peroxide biosensor based on the immobilization of horseradish peroxidase onto Au-modified titanium dioxide nanotube arrays

被引:246
作者
Kafi, A. K. M. [1 ]
Wu, Guosheng [1 ]
Chen, Aicheng [1 ]
机构
[1] Lakehead Univ, Dept Chem, Thunder Bay, ON P7B 5E1, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Au-modified titania nanotube arrays; HRP; Biosensors; Hydrogen peroxide; Methylene blue;
D O I
10.1016/j.bios.2008.06.004
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
In this study, we report on a promising H2O2 biosensor based on the co-immobilization of horseradish peroxidase (HRP) and chitosan onto Au-modified TiO2 nanotube arrays. The titania nanotube arrays were directly grown on a Ti substrate using anodic oxidation first; a gold thin film was then uniformly coated onto the TiO2 nanotube arrays by an argon plasma technique. The morphology and composition of the fabricated Au-modified TiO2 nanotube arrays were characterized by scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDS). Cyclic voltammetry and chronoamperometry were used to study and to optimize the performance of the resulting electrochemical biosensor. The effect of pH, applied electrode potential, the presence of the electron-mediator methylene blue, and the anodic oxidation time of the Ti substrate on the electrochemical biosensor has been systemically studied. Our electrochemical measurements show that the Au-modified TiO2 nanotube arrays provide excellent matrices for the immobilization of HRP and that the optimized electrochemical biosensor exhibits long linearity. a low detection limit, high stability and very good reproducibility for the detection of H2O2. Under the optimized conditions the linearity of the developed biosensor for the detection of H2O2 is observed from 5 x 10(-6) to 4 x 10(-4) mol l(-1) with a detection limit of 2 x 10(-6) mol l(-1) (based on the S/N = 3). (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:566 / 571
页数:6
相关论文
共 46 条
[1]   A mediator-free amperometric hydrogen peroxide biosensor based on HRP immobilized on a nano-Au/poly 2,6-pyridinediamine-coated electrode [J].
Cao, Shurui ;
Yuan, Ruo ;
Chai, Yaqin ;
Zhang, Lingyan ;
Li, Xuelian ;
Gao, Fengxian .
BIOPROCESS AND BIOSYSTEMS ENGINEERING, 2007, 30 (02) :71-78
[2]   Direct electrochemistry of heme proteins: effect of electrode surface modification by neutral surfactants [J].
Chattopadhyay, K ;
Mazumdar, S .
BIOELECTROCHEMISTRY, 2001, 53 (01) :17-24
[3]   Direct electrochemistry and electrocatalysis of horseradish peroxidase immobilized in sol-gel-derived ceramic-carbon nanotube nanocomposite film [J].
Chen, Hongjun ;
Dong, Shaojun .
BIOSENSORS & BIOELECTRONICS, 2007, 22 (08) :1811-1815
[4]   Amperometric hydrogen peroxide biosensor based on the immobilization of horseradish peroxidase (HRP) on the layer-by-layer assembly films of gold colloidal nanoparticles and toluidine blue [J].
Chen, SH ;
Yuan, R ;
Chai, YQ ;
Xu, L ;
Wang, N ;
Li, XN ;
Zhang, LY .
ELECTROANALYSIS, 2006, 18 (05) :471-477
[5]   Ordered electrochemically active films of hemoglobin, didodecyldimethylammonium ions, and clay [J].
Chen, XL ;
Hu, NF ;
Zeng, YH ;
Rusling, JF ;
Yang, J .
LANGMUIR, 1999, 15 (20) :7022-7030
[6]   ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY [J].
CLARK, LC ;
LYONS, C .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1962, 102 (01) :29-&
[7]   Electron-transfer reactivity and enzymatic activity of hemoglobin in a SP sephadex membrane [J].
Fan, CH ;
Wang, HY ;
Sun, S ;
Zhu, DX ;
Wagner, G ;
Li, GX .
ANALYTICAL CHEMISTRY, 2001, 73 (13) :2850-2854
[8]   Mediatorless biosensor for H2O2 based on recombinant forms of horseradish peroxidase directly adsorbed on polycrystalline gold [J].
Ferapontova, EE ;
Grigorenko, VG ;
Egorov, AM ;
Börchers, T ;
Ruzgas, T ;
Gorton, L .
BIOSENSORS & BIOELECTRONICS, 2001, 16 (03) :147-157
[9]   Amperometric hydrogen peroxide biosensor based on the immobilization of HRP on nano-Au/Thi/poly (p-aminobenzene sulfonic acid)-modified glassy carbon electrode [J].
Gao, Fengxian ;
Yuan, Ruo ;
Chai, Yaqin ;
Chen, Shihong ;
Cao, Shurui ;
Tang, Mingyu .
JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS, 2007, 70 (03) :407-413
[10]   Preferential orientation of an immunoglobulin in a glycolipid monolayer controlled by the disintegration kinetics of proteo-lipidic vesicles spread at an air-buffer interface [J].
Girard-Egrot, AP ;
Godoy, S ;
Chauvet, JP ;
Boullanger, P ;
Coulet, PR .
BIOCHIMICA ET BIOPHYSICA ACTA-BIOMEMBRANES, 2003, 1617 (1-2) :39-51