三维超高场7T高分辨磁敏感加权像静脉造影(英文)

被引:13
作者
Samuel Barnes [1 ]
Samantha Heller [2 ]
Daniel KSodickson [2 ]
EMark Haacke [1 ]
Robert IGrossman [2 ]
机构
[1] Department of Radiology,The MRI Institute for Biomedical Research,Detroit,MI ,USA
[2] Center for Biomedical Imaging,Department of Radiology,New York University Langone Medical Center,New York,NY ,USA
关键词
磁共振成像; 高场强; 静脉造影术; 磁敏感加权成像; 相位; 脑;
D O I
暂无
中图分类号
R445.2 [核磁共振成像];
学科分类号
100231 [临床病理学];
摘要
目的超高场磁共振具有高信噪比和独特的磁敏感对比,使其在无创性脑血管造影尤其是对小静脉的检测有明显优势。本文探讨如何在超高场磁共振7T优化和获取高质量的磁敏感加权像(SWI)静脉造影。方法选择10例正常志愿者作为研究对象,采集一系列7TSWI静脉造影数据并与3T结果作对比。选择参数TR=30~45ms,TE=13~26ms,带宽(BW)=80~140Hz/pixel,翻转角(FA)=10~25?;所有的数据用同样的图像后处理方式得到最小信号叠加投影(mIP)的SWI静脉造影像,并进行定量化分析。结果图像优化后,我们得到高分辨率的7T静脉造影图像。根据静脉血的T2*选择优化TE:16ms(7T),28ms(3T);FA:15?(3T和7T)。相对于3T,7TSWI图像有较高的信噪比和静脉与周围组织的对比度,并显示出更多的微小静脉。结论超高场SWI静脉造影对于显示微小静脉具有明显的优势。
引用
收藏
页码:83 / 93
页数:11
相关论文
共 8 条
[1]
MR venography of the human brain using susceptibility weighted imaging at very high field strength.[J].Peter J. Koopmans;Rashindra Manniesing;Wiro J. Niessen;Max A. Viergever;Markus Barth.Magnetic Resonance Materials in Physics; Biology and Medicine.2008, 1
[2]
Susceptibility-weighted imaging to visualize blood products and improve tumor contrast in the study of brain masses [J].
Sehgal, Vivek ;
Delproposto, Zachary ;
Haddar, Djamel ;
Haacke, E. Mark ;
Sloan, Andrew E. ;
Zamorano, Lucia J. ;
Barger, Geoffery ;
Hu, Jiani ;
Xu, Yingbiao ;
Prabhakaran, Karthik Praveen ;
Elangovan, Ilaya R. ;
Neelavalli, Jaladhar ;
Reichenbach, Juergen R. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 24 (01) :41-51
[3]
Extensive heterogeneity in white matter intensity in high-resolution T 2 * -weighted MRI of the human brain at 7.0 T.[J].Tie-Qiang Li;Peter van Gelderen;Hellmut Merkle;Lalith Talagala;Alan P. Koretsky;Jeff Duyn.Neuroimage.2006, 3
[4]
Susceptibility weighted imaging (SWI) [J].
Haacke, EM ;
Xu, YB ;
Cheng, YCN ;
Reichenbach, JR .
MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (03) :612-618
[5]
Early diagnosis of cerebral involvement in Sturge-Weber syndrome using high-resolution BOLD MR venography [J].
Mentzel, HJ ;
Dieckmann, A ;
Fitzek, C ;
Brandl, U ;
Reichenbach, JR ;
Kaiser, WA .
PEDIATRIC RADIOLOGY, 2005, 35 (01) :85-90
[6]
High-resolution three-dimensional contrast-enhanced blood oxygenation level-dependent magnetic resonance venography of brain tumors at 3 Tesla:: First clinical experience and comparison with 1.5 Tesla [J].
Barth, M ;
Nöbauer-Huhmann, IM ;
Reichenbach, JR ;
Mlynárik, V ;
Schöggl, A ;
Matula, C ;
Trattnig, S .
INVESTIGATIVE RADIOLOGY, 2003, 38 (07) :409-414
[7]
Imaging brain function in humans at 7 Tesla [J].
Yacoub, E ;
Shmuel, A ;
Pfeuffer, J ;
Van de Moortele, PF ;
Adriany, G ;
Andersen, P ;
Vaughan, JT ;
Merkle, H ;
Ugurbil, K ;
Hu, XP .
MAGNETIC RESONANCE IN MEDICINE, 2001, 45 (04) :588-594
[8]
A measure of compactness for 3D shapes.[J].E. Bribiesca.Computers and Mathematics with Applications.2000, 10