The John Insall Award No Functional Benefit After Unicompartmental Knee Arthroplasty Performed With Patient-specific Instrumentation: A Randomized Trial

被引:61
作者
Ollivier, Matthieu [1 ]
Parratte, Sebastien [1 ]
Lunebourg, Alexandre [1 ]
Viehweger, Elke [2 ]
Argenson, Jean-Noel [1 ]
机构
[1] Aix Marseille Univ, St Marguerite Hosp, Inst Locomot, Dept Orthoped & Traumatol, F-13274 Marseille, France
[2] Aix Marseille Univ, Timone Hosp, Dept Pediat Surg, F-13274 Marseille, France
关键词
GAIT; OUTCOMES; OSTEOARTHRITIS; PROSTHESIS; ALIGNMENT; TKA;
D O I
10.1007/s11999-015-4259-0
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
Background Component alignment can influence implant longevity as well as perhaps pain and function after uni-compartmental knee arthroplasty (UKA), but correct alignment is not consistently achieved. To increase the likelihood that good alignment will be achieved during surgery, smart tools such as robotics or patient-specific instrumentation (PSI) have been introduced. Questions/purposes We hypothesized that UKA performed with PSI would result in improved level gait as ascertained with three-dimensional analysis, implant positioning, and patient-reported outcomes measured by a validated scoring system when compared with conventional instrumentation 3 months and 1 year after surgery. Methods We randomized 60 patients into two groups using either the PSI technique or a conventional technique. All patients were operated on using the same technique and the same cemented metal-backed implant. Mean age of the patients was 63 +/- 4 years (range, 54-72 years) and mean body mass index was 28 +/- 3 kg/m(2). Patients were evaluated preoperatively, at 3 months, and 1 year after surgery by an independent observer blind to the type of technique. Gait parameters were assessed with three-dimensional analysis during level walking preoperatively and at 1 year, frontal and sagittal position of the implant was evaluated on full-length radiographs at 3 months, and subjective functional outcome and quality of life using routine questionnaires (SF-12, new Knee Society Score [KSS], Knee Injury and Osteoarthritis Outcome Score) at 3 months and 1 year. This study had 80% power to detect a 15% difference in walking speed at the p<0.05 level. Results One year after surgery, there were no differences between the two groups in the analyzed gait spatiotemporal parameters, respectively, for PSI UKA and conventional UKA : double limb support 31% (25%-54%) versus 30% (23%-56%; p = 0.67) and walking speed (1.59 m/s [0.86-1.87 m/s] versus 1.57 m/s [0.71-1.96 m/s]; p = 0.41). No difference was observed between the two groups in terms of lower limb alignment (PSI group 178 degrees +/- 3 degrees, conventional group 178 degrees +/- 4 degrees; p = 0.24) or implant positioning on mediolateral and anteroposterior radiographs. There were no differences in the functional score between the PSI and conventional TKA groups at 3 months and 1 year after surgery: KSS objective knee scores (PSI: 85 +/- 8 points at 3 months, 87 +/- 5 points at 1 year and conventionalinstrumentation: 82 +/- 8 points at 3 months 83 +/- 6 points at 1 year; p = 0.10) and functional activity scores were similar in both group (PSI: 71 +/- 12 points at 3 months and 74 +/- 7 points at 1 year versus conventional group: 73 +/- 11 points at 3 months and 75 +/- 6 at 1 year; p = 0.9). Conclusions Our observations suggest that PSI may confer small, if any, advantage in alignment, pain, or function after UKA. This argument can therefore not be used to justify the extra cost and uncertainty related to this technique. Level of Evidence Level I, therapeutic study.
引用
收藏
页码:60 / 68
页数:9
相关论文
共 24 条
[1]
No Benefit of Patient-specific Instrumentation in TKA on Functional and Gait Outcomes: A Randomized Clinical Trial [J].
Abdel, Matthew P. ;
Parratte, Sebastien ;
Blanc, Guillaume ;
Ollivier, Matthieu ;
Pomero, Vincent ;
Viehweger, Elke ;
Argenson, Jean-Noel A. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2014, 472 (08) :2468-2476
[2]
Ahlback S O, 1971, Nord Med, V85, P157
[3]
Unicompartmental knee Arthroplasty - Technique through a mini-incision [J].
Argenson, Jean-Noel A. ;
Parratte, Sebastien ;
Flecher, Xavier ;
Aubaniac, Jean-Manuel .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2007, (464) :32-36
[4]
Mini-invasive implantation of a unicompartimental medial knee prosthesis [J].
Argenson, JN ;
Flecher, X ;
Parratte, S .
REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 2006, 92 (02) :193-199
[5]
Higher revision risk for unicompartmental knee arthroplasty in low-volume hospitals [J].
Badawy, Mona ;
Espehaug, Birgitte ;
Indrekvam, Kari ;
Havelin, Leif I. ;
Furnes, Ove .
ACTA ORTHOPAEDICA, 2014, 85 (04) :342-347
[6]
Accuracy and early outcomes in medial unicompartmental knee arthroplasty performed using patient specific instrumentation [J].
Bell, Stuart W. ;
Stoddard, James ;
Bennett, Caroline ;
London, Nicholas J. .
KNEE, 2014, 21 :S33-S36
[7]
Unicompartmental knee arthroplasty with the Oxford prosthesis in patients with medial compartment arthritis [J].
Emerson, Roger H. ;
Higgins, Linda L. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2008, 90A (01) :118-122
[8]
Function and quality of life following medial unicompartmental knee arthroplasty in patients 60 years of age or younger [J].
Felts, E. ;
Parratte, S. ;
Pauly, V. ;
Aubaniac, J-M ;
Argenson, J-N .
ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2010, 96 (08) :861-867
[9]
Unicompartmental Knee Arthroplasty with Use of Novel Patient-Specific Resurfacing Implants and Personalized Jigs [J].
Fitz, Wolfgang .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A :69-76
[10]
Alignment influences wear in the knee after medial unicompartmental arthroplasty [J].
Hernigou, P ;
Deschamps, G .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (423) :161-165