Bacteria-based biosensor for determination of hydrogen peroxide

被引:4
作者
Tai, GY [1 ]
Wen, ML [1 ]
Wang, CY [1 ]
机构
[1] YUNNAN UNIV,DEPT CHEM,KUNMING 650091,PEOPLES R CHINA
关键词
D O I
10.1006/mchj.1996.0021
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A bacterial biosensor that immobilizes living bacteria of strain Bacillus subtilis AS 1.398 are coupled to a Clark-type oxygen electrode to determine hydrogen peroxide. The H2O2 is catalyzed by catalase from the bacteria to produce H2O and O-2. This sensor is advantageous in terms of linearity (10 to 2000 mu M H2O2), lifetime (65 days), and selectivity (no significant interference from some amino acids, metal ions, polyphenols, glucose, and ascorbic acid), especially because bacteria can be used as 2 catalase enzyme membrane that can reproduce itself. The correlation coefficient is 0.999. (C) 1996 Academic Press, Inc.
引用
收藏
页码:152 / 157
页数:6
相关论文
共 29 条
[1]   LUMINOL CHEMILUMINESCENCE REACTION CATALYZED BY A MICROBIAL PEROXIDASE [J].
AKIMOTO, K ;
SHINMEN, Y ;
SUMIDA, M ;
ASAMI, S ;
AMACHI, T ;
YOSHIZUMI, H ;
SAEKI, Y ;
SHIMIZU, S ;
YAMADA, H .
ANALYTICAL BIOCHEMISTRY, 1990, 189 (02) :182-185
[2]   KOHLRABI-BASED AMPEROMETRIC BIOSENSOR FOR HYDROGEN-PEROXIDE MEASUREMENT [J].
CHEN, L ;
LIN, MS ;
HARA, M ;
RECHNITZ, GA .
ANALYTICAL LETTERS, 1991, 24 (01) :1-14
[3]   SPECTROFLUORIMETRIC DETERMINATION OF HYDROGEN-PEROXIDE BASED ON THE CATALYTIC EFFECT OF PEROXIDASE-LIKE MANGANESE TETRAKIS(SULPHOPHENYL) PORPHYRIN ON THE OXIDATION OF HOMOVANILLIC-ACID [J].
CI, YX ;
WANG, F .
ANALYTICA CHIMICA ACTA, 1990, 233 (02) :299-302
[4]  
CI YX, 1990, ANAL CHIM ACTA, V237, P497
[5]  
CI YX, 1989, GAODENG XUEXIAO HUAX, V10, P229
[6]   SPECTROPHOTOMETRIC DETERMINATION OF HYDROGEN-PEROXIDE WITH LEUCO PATENT BLUE VIOLET [J].
CLAPP, PA ;
EVANS, DF .
ANALYTICA CHIMICA ACTA, 1991, 243 (02) :217-220
[7]   CHEMICALLY IMMOBILIZED ENZYME ELECTRODES FOR HYDROGEN-PEROXIDE DETERMINATION [J].
COSGROVE, M ;
MOODY, GJ ;
THOMAS, JDR .
ANALYST, 1988, 113 (12) :1811-1815
[8]   IMMOBILIZATION OF CATALASE ON MEMBRANES OF POLY(ETHYLENE)-G-CO-ACRYLIC ACID AND POLY(TETRAFLUOROETHYLENE)-G-CO-ACRYLIC ACID AND THEIR APPLICATION IN HYDROGEN-PEROXIDE ELECTROCHEMICAL SENSORS [J].
DASILVA, MA ;
GIL, MH ;
PIEDADE, AP ;
REDINHA, JS ;
BRETT, AMO ;
COSTA, JMC .
JOURNAL OF POLYMER SCIENCE PART A-POLYMER CHEMISTRY, 1991, 29 (02) :269-274
[9]  
DOMINGUEZ P, 1989, Analytical Proceedings, V26, P387
[10]   FLUOROMETRIC FLOW-INJECTION DETERMINATION OF AQUEOUS PEROXIDES AT NANOMOLAR LEVEL USING MEMBRANE REACTORS [J].
HWANG, H ;
DASGUPTA, PK .
ANALYTICAL CHEMISTRY, 1986, 58 (07) :1521-1524