Performance of individual cells in polymer electrolyte membrane fuel cell stack under-load cycling conditions

被引:34
作者
Bose, A. [1 ,2 ]
Babburi, P.
Kumar, R. [3 ]
Myers, D. [3 ]
Mawdsley, J. [3 ]
Milhuff, J. [3 ]
机构
[1] Univ Houston, Dept Engn Technol, Houston, TX 77204 USA
[2] Univ Houston, Texas Ctr Superconduct, Houston, TX 77204 USA
[3] Argonne Natl Lab, Chem Sci & Engn Div, Argonne, IL 60439 USA
关键词
Polymer electrolyte fuel cells; Performance degradation; Dynamic load cycling; Durability; OXYGEN REDUCTION; PART I; DEGRADATION; CATALYST; DURABILITY; ASSEMBLIES; PARAMETERS; MANAGEMENT; ISSUES;
D O I
10.1016/j.jpowsour.2013.05.156
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070305 [高分子化学与物理];
摘要
The performance of a ten-cell 50 cm(2) 100 W polymer electrolyte membrane fuel cell (PEMFC) stack was evaluated under dynamic load cycling conditions utilizing the 2005 United States Department of Energy durability test protocol for PEFCs. An enhancement of performance was observed during the first 240 h, while an irreversible degradation of stack performance was observed after 480 h ( similar to 4700 cycles). In particular, the stack voltage at 100 mA cm(-2) was decreased by 2.8% after 480 h and individual cell voltage was decreased up to 8%. An analysis of cell overpotentials for activation, Ohmic, and mass transport losses revealed that the predominant source of performance degradation was due to kinetic losses. The loss of catalyst utilization was estimated to be 39% based on the electrochemically active surface area (ECSA) measurements. Electron microscopic images of some of the cells showed growth in cathode Pt particle size from 5.3 to 6.2 nm. However, these microscopic images did not show any membrane damage or electrode thinning. Severe degradation of both the anode and cathode silicone gasket seals was observed during the durability test. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:964 / 972
页数:9
相关论文
共 33 条
[1]
[Anonymous], 2011, FUEL CELLS
[2]
Barbir F, 2005, SUSTAIN WORLD SER, P1
[3]
Scientific aspects of polymer electrolyte fuel cell durability and degradation [J].
Borup, Rod ;
Meyers, Jeremy ;
Pivovar, Bryan ;
Kim, Yu Seung ;
Mukundan, Rangachary ;
Garland, Nancy ;
Myers, Deborah ;
Wilson, Mahlon ;
Garzon, Fernando ;
Wood, David ;
Zelenay, Piotr ;
More, Karren ;
Stroh, Ken ;
Zawodzinski, Tom ;
Boncella, James ;
McGrath, James E. ;
Inaba, Minoru ;
Miyatake, Kenji ;
Hori, Michio ;
Ota, Kenichiro ;
Ogumi, Zempachi ;
Miyata, Seizo ;
Nishikata, Atsushi ;
Siroma, Zyun ;
Uchimoto, Yoshiharu ;
Yasuda, Kazuaki ;
Kimijima, Ken-ichi ;
Iwashita, Norio .
CHEMICAL REVIEWS, 2007, 107 (10) :3904-3951
[4]
PEM fuel cell electrocatalyst durability measurements [J].
Borup, Rod L. ;
Davey, John R. ;
Garzon, Fernando H. ;
Wood, David L. ;
Inbody, Michael A. .
JOURNAL OF POWER SOURCES, 2006, 163 (01) :76-81
[5]
Optimization of the performance of polymer electrolyte fuel cell membrane-electrode assemblies: Roles of curing parameters on the catalyst and ionomer structures and morphology [J].
Bose, Anima B. ;
Shaik, Ruhulla ;
Mawdsley, Jennifer .
JOURNAL OF POWER SOURCES, 2008, 182 (01) :61-65
[6]
Performance of polymer electrolyte membrane fuel cell (PEMFC) stacks Part I. Evaluation and simulation of an air-breathing PEMFC stack [J].
Chu, D ;
Jiang, RZ .
JOURNAL OF POWER SOURCES, 1999, 83 (1-2) :128-133
[7]
Comparative studies of polymer electrolyte membrane fuel cell stack and single cell [J].
Chu, D ;
Jiang, RZ .
JOURNAL OF POWER SOURCES, 1999, 80 (1-2) :226-234
[8]
Durability and degradation issues of PEM fuel cell components [J].
de Bruijn, F. A. ;
Dam, V. A. T. ;
Janssen, G. J. M. .
FUEL CELLS, 2008, 8 (01) :3-22
[9]
Debe M.K., 2010, ADV CATHODE CATALYST
[10]
Instability of Pt/C electrocatalysts in proton exchange membrane fuel cells - A mechanistic investigation [J].
Ferreira, PJ ;
la O', GJ ;
Shao-Horn, Y ;
Morgan, D ;
Makharia, R ;
Kocha, S ;
Gasteiger, HA .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2005, 152 (11) :A2256-A2271