Implantable intravascular defibrillator: Defibrillation thresholds of an intravascular cardioverter-defibrillator compared with those of a conventional ICD in humans

被引:7
作者
Neuzil, Petr [1 ]
Reddy, Vivek Y. [2 ]
Merkely, Bela [3 ]
Geller, Laszlo [3 ]
Molnar, Levente [3 ]
Bednarek, Jacek [4 ]
Bartus, Krzysztof [4 ]
Richey, Mark [5 ]
Ransbury, T. J. [5 ]
Sanders, William. E., Jr. [6 ]
机构
[1] Hosp Na Homolce, Prague, Czech Republic
[2] Mt Sinai Sch Med, New York, NY USA
[3] Semmelweis Univ, Ctr Heart, H-1085 Budapest, Hungary
[4] Jagiellonian Univ, John Paul Hosp 2, Krakow, Poland
[5] InnerPulse, Res Triangle Pk, NC USA
[6] Univ N Carolina, Bethesda, MD 20814 USA
关键词
Defibrillation threshold; Implantable cardioverter defibrillator; Intravascular defibrillator; PACEMAKER; PREVENTION; GUIDELINES;
D O I
10.1016/j.hrthm.2013.10.035
中图分类号
R5 [内科学];
学科分类号
100201 [内科学];
摘要
BACKGROUND A percutaneous intravascular cardioverter-defibrillator (PICD) has been developed with a right ventricular (RV) single-coil lead and titanium electrodes in the superior vena cava (SVC)-brachiocephalic vein (BCV) region and the inferior vena cava (IVC). OBJECTIVE To compare defibrillation thresholds (DFTs) of the PICD with those of a conventional ICD in humans. METHODS Ten patients with ischemic cardiomyopathy and ejection fraction <= 35% were randomized to initial testing with either PICD or conventional ICD. A standard dual-coil lead was positioned in the RV apex. If randomized to PICD, the device was placed into the vasculature such that 1 titanium electrode was positioned in the SVC-BCV region and the second in the IVC. For PICD DFTs, the RV coil of the conventional ICD lead was connected to the PICD mandrel [shock vector: RV(+) to SVC-BCV(-) + IVC (-)]. When testing the conventional ICD, a subcutaneous pocket was formed in the left pectoralis region and the ICD was connected to the lead system and positioned in the pocket [shock vector: RV(+) to SVC (-) + active can(-)]. Each device was removed before testing with the other. A step-down binary search protocol determined the DFT, with the initial shock being 9 J. RESULTS The mean PICD DFT was 7.6 +/- 3.3 J, and the conventional ICD system demonstrated a mean DFT of 9.5 +/- 4.7 J(N = 10; paired t test, P = .28). CONCLUSION The intravascular defibrillator has DFTs similar to those of commercially available ICDs.
引用
收藏
页码:210 / 215
页数:6
相关论文
共 16 条
[1]
Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure [J].
Bardy, GH ;
Lee, KL ;
Mark, DB ;
Poole, JE ;
Packer, DL ;
Boineau, R ;
Domanski, M ;
Troutman, C ;
Anderson, J ;
Johnson, G ;
McNulty, SE ;
Clapp-Channing, N ;
Davidson-Ray, LD ;
Fraulo, ES ;
Fishbein, DP ;
Luceri, RM ;
Ip, JH .
NEW ENGLAND JOURNAL OF MEDICINE, 2005, 352 (03) :225-237
[2]
Sex differences in the use of implantable cardioverter-defibrillators for primary and secondary prevention of sudden cardiac death [J].
Curtis, Lesley H. ;
Al-Khatib, Sana M. ;
Shea, Alisa M. ;
Hammill, Bradley G. ;
Hernandez, Adrian F. ;
Schulman, Kevin A. .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2007, 298 (13) :1517-1524
[3]
Histological findings around electrodes in pacemaker and implantable cardioverter-defibrillator patients: comparison of steroid-eluting and non-steroid-eluting electrodes [J].
Dvorak, Petr ;
Novak, Miroslav ;
Kamaryt, Pavel ;
Slana, Bronislava ;
Lipoldova, Jolana ;
Dvorak, Pavel .
EUROPACE, 2012, 14 (01) :117-123
[4]
Morphologic and immunohistochemical observations of tissues surrounding retrieved transvenous pacemaker leads [J].
Esposito, M ;
Kennergren, C ;
Holmström, N ;
Nilsson, S ;
Eckerdal, J ;
Thomsen, P .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 2002, 63 (05) :548-558
[5]
Go AS, 2013, CIRCULATION, V127, pE6, DOI 10.1161/CIR.0b013e31828124ad
[6]
Merkely B, 2011, PACING CLIN ELECTROP, V34, P1414
[7]
Chronic Implantation of Intravascular Cardioverter Defibrillator in a Canine Model: Device Stability, Vascular Patency, and Anchor Histology [J].
Merkely, Bela ;
Molnar, Levente ;
Geller, Laszlo ;
Neuzil, Petr ;
Skoda, Jan ;
Bednarek, Jacek ;
Bartus, Krzysztof ;
Reddy, Vivek Y. ;
Sanders, William E., Jr. .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2013, 36 (10) :1251-1258
[8]
Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction [J].
Moss, AJ ;
Zareba, W ;
Hall, WJ ;
Klein, H ;
Wilber, DJ ;
Cannom, DS ;
Daubert, JP ;
Higgins, SL ;
Brown, MW ;
Andrews, ML .
NEW ENGLAND JOURNAL OF MEDICINE, 2002, 346 (12) :877-883
[9]
Sanders W, 2010, EUR HEART J, V31, P837
[10]
Implantable Intravascular Defibrillator: Evaluation of Defibrillation Waveforms with Inferior Vena Cava Electrode System [J].
Sanders, William E., Jr. ;
Malkin, Robert A. ;
Richey, Mark W. ;
Masson, Stephen C. ;
Ransbury, Terrance J. ;
Urtz, Mark W. ;
Ideker, Raymond E. .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2011, 34 (05) :577-583