Chronic Implantation of Intravascular Cardioverter Defibrillator in a Canine Model: Device Stability, Vascular Patency, and Anchor Histology

被引:4
作者
Merkely, Bela [1 ]
Molnar, Levente [1 ]
Geller, Laszlo [1 ]
Neuzil, Petr [2 ]
Skoda, Jan [2 ]
Bednarek, Jacek [3 ]
Bartus, Krzysztof [3 ]
Reddy, Vivek Y. [4 ]
Sanders, William E., Jr. [5 ]
机构
[1] Semmelweis Univ, Ctr Heart, H-1085 Budapest, Hungary
[2] Hosp Homolce, Prague, Czech Republic
[3] Jagiellonian Univ, John Paul II Hosp, Krakow, Poland
[4] Mt Sinai Sch Med, New York, NY USA
[5] Univ N Carolina, Chapel Hill, NC USA
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2013年 / 36卷 / 10期
关键词
implantable cardioverter-defibrillator; implantable intravascular cardioverter-defibrillator; percutaneous implantation; chronic canine model; PREVENTION; PACEMAKER; GUIDELINES; TISSUES;
D O I
10.1111/pace.12247
中图分类号
R5 [内科学];
学科分类号
100201 [内科学];
摘要
IntroductionA percutaneously placed implantable intravascular defibrillator (PICD) has been developed with a right ventricular (RV) single-coil lead and titanium electrodes in the superior vena cava (SVC) and the inferior vena cava (IVC). This study evaluated implant techniques, device stability, and anchor histology of the PICD over 9 months in a canine model. MethodsTwenty-four hounds (wt = 30-55 kg) were anesthetized and a custom sheath introduced into the right femoral vein. The PICD was advanced over a wire and positioned with the titanium electrodes (cathodes) in the SVC and the IVC. A nitinol anchor secured the device in the jugular. The RV lead was positioned in the RV apex and screwed into place. The catheters, wires, and sheath were removed with an average implant time of 14 minutes. In one group of animals (n = 13), serial venograms were performed at 7 days, 14 days, and 28 days. In a second group (n = 6) and third group (n = 5), venograms were also performed at 90 days and 270 days, respectively. Six canines were sacrificed and anchor histologic examination done at 90 days. ResultsAll implants were successful with no surgical complications observed. Devices (N = 24) remained appropriately positioned with no anchor migration. Histology at 90 days showed 98% endothelialization of the anchor. Venograms revealed patent IVC and jugular veins in all animals at every time point examined. ConclusionsThe PICD can be rapidly and chronically implanted in animals. Long-term intravascular defibrillator placement is feasible in a canine model.
引用
收藏
页码:1251 / 1258
页数:8
相关论文
共 19 条
[1]
Budd-Chiari Syndrome Caused by Multiple Membranous Obstruction of the Inferior Vena Cava in a Young Man [J].
Chen, Hongqiang ;
Cheng, Yu ;
Ning, Shanglei ;
Chen, Yuxin .
ANNALS OF VASCULAR SURGERY, 2011, 25 (08) :1139.e5-1139.e7
[2]
Sex differences in the use of implantable cardioverter-defibrillators for primary and secondary prevention of sudden cardiac death [J].
Curtis, Lesley H. ;
Al-Khatib, Sana M. ;
Shea, Alisa M. ;
Hammill, Bradley G. ;
Hernandez, Adrian F. ;
Schulman, Kevin A. .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2007, 298 (13) :1517-1524
[3]
Histological findings around electrodes in pacemaker and implantable cardioverter-defibrillator patients: comparison of steroid-eluting and non-steroid-eluting electrodes [J].
Dvorak, Petr ;
Novak, Miroslav ;
Kamaryt, Pavel ;
Slana, Bronislava ;
Lipoldova, Jolana ;
Dvorak, Pavel .
EUROPACE, 2012, 14 (01) :117-123
[4]
Morphologic and immunohistochemical observations of tissues surrounding retrieved transvenous pacemaker leads [J].
Esposito, M ;
Kennergren, C ;
Holmström, N ;
Nilsson, S ;
Eckerdal, J ;
Thomsen, P .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 2002, 63 (05) :548-558
[5]
Implantable Cardioverter Defibrillator Therapy for Primary Prevention of Sudden Cardiac Death after Myocardial Infarction: Implications of International Guidelines [J].
Foley, Paul W. X. ;
Addison, Clara E. ;
Whinney, Stephanie B. ;
Patel, Kiran ;
Cunningham, David ;
Frenneaux, Michael P. ;
Leyva, Francisco .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2009, 32 :S131-S134
[6]
Polymethylmethacrylate (PMMA) as an embedding medium preserving tissues and foreign materials encroaching in endovascular devices [J].
Guidoin, R. ;
Zhang, Z. ;
Douville, Y. ;
Basle, M. -F. ;
Grizon, F. ;
Marinov, G. R. ;
Zarins, C. K. ;
Legrand, A. P. ;
Guzman, R. .
ARTIFICIAL CELLS BLOOD SUBSTITUTES AND BIOTECHNOLOGY, 2006, 34 (03) :349-366
[7]
Differences in encapsulating lead tissue in patients who underwent transvenous lead removal [J].
Kolodzinska, Agnieszka ;
Kutarski, Andrzej ;
Koperski, Lukasz ;
Grabowski, Marcin ;
Malecka, Barbara ;
Opolski, Grzegorz .
EUROPACE, 2012, 14 (07) :994-1001
[8]
Percutaneous caval stent valve implantation: investigation of an interventional approach for treatment of tricuspid regurgitation [J].
Lauten, Alexander ;
Figulla, Hans R. ;
Willich, Christoph ;
Laube, Adrian ;
Rademacher, Wilma ;
Schubert, Harald ;
Bischoff, Sabine ;
Ferrari, Markus .
EUROPEAN HEART JOURNAL, 2010, 31 (10) :1274-1281
[9]
Long-Term Efficacy of Stent Placement for Treating Inferior Vena Cava Stenosis Following Liver Transplantation [J].
Lee, Jae Myeong ;
Ko, Gi-Young ;
Sung, Kyu-Bo ;
Gwon, Dong Il ;
Yoon, Hyun-Ki ;
Lee, Sung-Gyu .
LIVER TRANSPLANTATION, 2010, 16 (04) :513-519
[10]
Merkely B, 2011, PACING CLIN ELECTROP, V34, P1414