Fabrication of carbon microelectrodes with a micromolding technique and their use in microchip-based flow analyses

被引:53
作者
Kovarik, ML [1 ]
Torrence, NJ [1 ]
Spence, DM [1 ]
Martin, RS [1 ]
机构
[1] St Louis Univ, Dept Chem, St Louis, MO 63103 USA
关键词
D O I
10.1039/b401380h
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this paper, we report a new technique to pattern carbon microelectrodes for use in microfluidics. This technique, termed micromolding of carbon inks, uses poly(dimethylsiloxane) (PDMS) microchannels to define the size of the microelectrode. First, PDMS microchannels of the approximate dimensions desired for the microelectrode are made by soft lithography. The PDMS is then reversibly sealed to a substrate and the microchannels are filled with carbon ink. After a heating step the PDMS mold is removed, leaving a carbon microelectrode with a size slightly smaller than the original PDMS microchannel. The resulting microelectrode (27 mum wide and 6 mum in height) can be reversibly sealed to a PDMS-based flow channel. Fluorescence microscopy showed that no leakage occurred around the chip/electrode seal, even up to flow rates of 10 muL min(-1). The electrode was characterized by microchip-based flow injection analysis. Injections of catechol in Hank's Balanced Salt Solution (pH 7.4), showed a linear response from 2 mM to 10 muM (r(2) = 0.995), with a sensitivity of 56.5 pA muM(-1) and an estimated limit of detection of 2 muM (0.27 picomole, S/N = 3). Reproducibility of the electrode response was shown by repeated injections (n = 10) of a 500 muM catechol solution, resulting in a RSD of 4.6%. Finally, selectivity was demonstrated by coating the microelectrode with Nafion, a perfluoronated cation exchange polymer. Dopamine exhibited a response at the modified microelectrode while ascorbic acid was rejected by the Nafion-coating. These electrodes provide inexpensive detectors for microfluidic applications while also being viable alternatives to use of other carbon microelectrode materials, such as carbon fibers. Furthermore, the manner in which the microelectrodes are produced will be of interest to researchers who do not have access to state of the art microfabrication facilities.
引用
收藏
页码:400 / 405
页数:6
相关论文
共 49 条
[1]  
BALDWIN RP, 2003, ANAL CHEM, V75, P3643
[2]  
Beh WS, 1999, ADV MATER, V11, P1038, DOI 10.1002/(SICI)1521-4095(199908)11:12<1038::AID-ADMA1038>3.0.CO
[3]  
2-L
[4]  
Bott A., 1995, Curr, P64
[5]   Chip-based capillary electrophoresis/mass spectrometry determination of carnitines in human urine [J].
Deng, YZ ;
Henion, J ;
Li, JJ ;
Thibault, P ;
Wang, C ;
Harrison, DJ .
ANALYTICAL CHEMISTRY, 2001, 73 (03) :639-646
[6]   Microfabricated 384-lane capillary array electrophoresis bioanalyzer for ultrahigh-throughput genetic analysis [J].
Emrich, CA ;
Tian, HJ ;
Medintz, IL ;
Mathies, RA .
ANALYTICAL CHEMISTRY, 2002, 74 (19) :5076-5083
[7]   PERMEABILITY OF GLUCOSE AND OTHER NEUTRAL SPECIES THROUGH RECAST PERFLUOROSULFONATED IONOMER FILMS [J].
FAN, ZH ;
HARRISON, DJ .
ANALYTICAL CHEMISTRY, 1992, 64 (11) :1304-1311
[8]   Contact conductivity detection in poly(methyl methacylate)-based microfluidic devices for analysis of mono- and polyanionic molecules [J].
Galloway, M ;
Stryjewski, W ;
Henry, A ;
Ford, SM ;
Llopis, S ;
McCarley, RL ;
Soper, SA .
ANALYTICAL CHEMISTRY, 2002, 74 (10) :2407-2415
[9]   Direct determination of carbohydrates, amino acids, and antibiotics by microchip electrophoresis with pulsed amperometric detection [J].
García, CD ;
Henry, CS .
ANALYTICAL CHEMISTRY, 2003, 75 (18) :4778-4783
[10]  
Gawron AJ, 2001, ELECTROPHORESIS, V22, P242, DOI 10.1002/1522-2683(200101)22:2<242::AID-ELPS242>3.0.CO