Fibre optic biosensor for the determination of D-glucose based on absorption changes of immobilized glucose oxidase

被引:15
作者
Chudobova, I
Vrbova, E
Kodicek, M
Janovcova, J
Kas, J
机构
[1] Institute of Chemical Technology, Dept. of Biochem. and Microbiology, CZ-166 Prague 6
关键词
biosensors; glucose oxidase; glucose; fibre optic biosensor; soft drinks;
D O I
10.1016/0003-2670(95)00471-8
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Glucose oxidase was covalently attached on a nylon net and the decrease of absorption of its prosthetic group (FAD) related to its reduction by glucose was determined. The analytical range from 2 to 10 mM (0.036-0.18% w/v) of glucose was achieved; both response (10s to 5 min) and regeneration times (2-15 min) of an enzyme layer were considerably dependent on the glucose concentration measured. Storage stability of the enzyme layer was longer than 30 months and the operational stability more than 200 analyses. The optimum pH value of the enzyme layer was 5.8, which accords well with the value of a free enzyme. Maximum activity of the enzyme layer was found at 37 degrees C, nevertheless, the conventional temperature of 30 degrees C was used for further experiments. The biosensor behaviour was tested in different buffers and 0.1 M citrate buffer was chosen as the most suitable one. The detection limit (2 mM of glucose) was influenced by dissolved oxygen: removal of oxygen by bubbling with nitrogen decreased the detection limit to 0.5 mM; on the contrary, the addition of catalase, which raises the amount of available oxygen, elevated it significantly. The biosensor prepared was tested on real samples of soft drinks; the results obtained were comparable with an amperometric and a spectrophotometric enzyme analysis.
引用
收藏
页码:103 / 110
页数:8
相关论文
共 22 条
[11]   A FAST RESPONDING FIBER OPTIC GLUCOSE BIOSENSOR BASED ON AN OXYGEN OPTRODE [J].
SCHAFFAR, BPH ;
WOLFBEIS, OS .
BIOSENSORS & BIOELECTRONICS, 1990, 5 (02) :137-148
[12]  
SCHMIDT HL, 1992, SENSORS, V3, P761
[13]   AFFINITY SENSOR - A NEW TECHNIQUE FOR DEVELOPING IMPLANTABLE SENSORS FOR GLUCOSE AND OTHER METABOLITES [J].
SCHULTZ, JS ;
MANSOURI, S ;
GOLDSTEIN, IJ .
DIABETES CARE, 1982, 5 (03) :245-253
[14]   OPTICAL SENSORS .34. FIBER OPTIC GLUCOSE BIOSENSOR WITH AN OXYGEN OPTRODE AS THE TRANSDUCER [J].
TRETTNAK, W ;
LEINER, MJP ;
WOLFBEIS, OS .
ANALYST, 1988, 113 (10) :1519-1523
[15]   FULLY REVERSIBLE FIBRE-OPTIC GLUCOSE BIOSENSOR BASED ON THE INTRINSIC FLUORESCENCE OF GLUCOSE-OXIDASE [J].
TRETTNAK, W ;
WOLFBEIS, OS .
ANALYTICA CHIMICA ACTA, 1989, 221 (02) :195-203
[16]  
TRETTNAK W, 1988, BIOSENSORS, V4, P15
[17]  
Trinder P., 1969, J CLIN PATHOL, V22, P158, DOI DOI 10.1177/000456326900600108
[19]  
UWIRA N, 1984, ADV EXP MED BIOL, V169, P913
[20]   APPLICATION OF THE UGI REACTION FOR THE PREPARATION OF ENZYME ELECTRODES [J].
VRBOVA, E ;
MAREK, M .
ANALYTICA CHIMICA ACTA, 1990, 239 (02) :263-268