Bone registration method for robot assisted surgery: Pedicle screw insertion

被引:9
作者
AbdelMalek, K
McGowan, DP
Goel, VK
Kowalski, D
Smith, SB
机构
[1] Department of Mechanical Engineering, University of Iowa, Iowa, LA
[2] Department of Surgery, Veteran's Adminisïration Medical Center, Des Moines, IA
[3] Department of Biomédical Engineering, University of Iowa, Iowa, LA
[4] Department of Orthopaedic Surgery, Indiana University, Indianapolis, IN
关键词
robotic assisted surgery; orthopaedics; pedicle screws; internal fixation; preoperative planning; registration;
D O I
10.1243/0954411971534331
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A registration method that identifies bone geometry with respect to a robotic manipulator arm is presented. Although the method is generally applicable to many orthopaedic internal fixation procedures, it was only demonstrated for the insertion of pedicle screws in vertebral bodies for spine fixation. The method relies upon obtaining an impression of the vertebral bodies. Computerized tomography (CT) scans of both vertebrae and mould are reconstructed using a computer aided engineering (CAE) system. From the reconstructions, the surgeon is able to do preoperative planning including selection of pedicle screw diameter, direction of screw through pedicle, point of entry and length of engagement. The three-dimensional models are then meshed to determine positions of the surgeon's preoperative plan relative to the mould. Intra-operative positions are defined in space by a mechanical fixture rigidly attached to the mould and designed to allow a manipulator end-effector to recognize the global coordinates of the in vivo spine. The theory and methodology were validated using a five-axis manipulator arm. This initial presentation assumes and allows no relative motion between vertebrae in vivo.
引用
收藏
页码:221 / 233
页数:13
相关论文
共 80 条
  • [1] ABDELMALEK K, 1993, THESIS U PENNSYLVANI
  • [2] COMPUTER-ASSISTED PEDICLE SCREW FIXATION - A FEASIBILITY STUDY
    AMIOT, LP
    LABELLE, H
    DEGUISE, JA
    SATI, M
    BRODEUR, P
    RIVARD, CH
    [J]. SPINE, 1995, 20 (10) : 1208 - 1212
  • [3] [Anonymous], 1964, J. Appl. Mech., Transaction of ASME
  • [4] AULT T, 1994, P 1 INT S MED ROB CO
  • [5] *AUT CORP, AUT REF MAN
  • [6] BARGAR WL, 1994, P 1 INT S MED ROB CO
  • [7] BARGAR WL, 1994, P AM AC ORTH SURG AN
  • [8] BENABID AL, 1987, APPL NEUROPHYSIOL, V50, P153
  • [9] PEDICLE DIAMETER DETERMINED BY COMPUTED-TOMOGRAPHY - ITS RELEVANCE TO PEDICLE SCREW FIXATION IN THE LUMBAR SPINE
    BERNARD, TN
    SEIBERT, CE
    [J]. SPINE, 1992, 17 (06) : S160 - S163
  • [10] Bouazza-Marouf K, 1995, Proc Inst Mech Eng H, V209, P51, DOI 10.1243/PIME_PROC_1995_209_316_02