Heavy metal ions detection in solution, in sol-gel and with grafted porphyrin monolayers

被引:56
作者
Delmarre, D [1 ]
Méallet, R [1 ]
Bied-Charreton, C [1 ]
Pansu, RB [1 ]
机构
[1] ENS, PPSM, CNRS, URA 1906, F-94235 Cachan, France
关键词
porphyrin; sol-gel; multi-layer; heavy metal; sensor;
D O I
10.1016/S1010-6030(99)00046-5
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The detection of heavy metal ions - Hg2+, Pb2+, Cd2+ - by a free base porphyrin, 5,10,15,20-tetra(4-N-methylpyridyl)porphyrin (TMPyP), was studied. The porphyrin was either adsorbed in sol-gel matrix (TMOS) or grafted on glass surfaces. Detection limit was 10(-7) mol/l for mercury and cadmium, and 10(-5) mol/l for lead. Apparent association constants were calculated at pH = 7: pK (Cd2+) = -5.2; pK (Pb2+) = -4; and at pH = 4 pK (Hg2+) = -5.7. Both the shift of the Soret band and the change in fluorescence lifetime enabled the identification of the metal ions. In sol-gel, detection limits were found to be 10(-3) mol/l but 90% of the metal salts were trapped by the matrix. In sol-gel we have shown that the ions were pumped by the matrix at a concentration of 1.5 x 10(-5) mol/ml of sol-gel. The sol-gel limits both the reaction time and the detection threshold. No such effect is observed for grafted monolayers. A reaction time of 30 min and a detection limit of 10(-6) mol/l were measured for Hg2+ salts. (C) 1999 Elsevier Science S.A. All rights reserved.
引用
收藏
页码:23 / 28
页数:6
相关论文
共 23 条
[1]   Fluorescence quenching and complexation behaviour of tetraphenylporphyrin with some divalent metal ions [J].
Azim, SA ;
ElKemary, MA ;
ElDaly, SA ;
ElDaly, HA ;
ElKhouly, ME ;
Ebeid, EM .
JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS, 1996, 92 (05) :747-751
[2]   IMPREGNATION OF A PH-SENSITIVE DYE INTO SOL-GELS FOR FIBER OPTIC CHEMICAL SENSORS [J].
BADINI, GE ;
GRATTAN, KTV ;
TSEUNG, ACC .
ANALYST, 1995, 120 (04) :1025-1028
[3]   Metalloporphyrinosilicas: A new class of hybrid organic-inorganic materials acting as selective biomimetic oxidation catalysts [J].
Battioni, P ;
Cardin, E ;
Louloudi, M ;
Schollhorn, B ;
Spyroulias, GA ;
Mansuy, D ;
Traylor, TG .
CHEMICAL COMMUNICATIONS, 1996, (17) :2037-2038
[4]   AN OPTICAL SENSOR FOR THE DETECTION OF HEAVY-METAL IONS [J].
CZOLK, R ;
REICHERT, J ;
ACHE, HJ .
SENSORS AND ACTUATORS B-CHEMICAL, 1992, 7 (1-3) :540-543
[5]   SOL-GEL CONDENSATION OF RAPIDLY HYDROLYZED SILICON ALKOXIDES - A JOINT SI-29 NMR AND SMALL-ANGLE X-RAY-SCATTERING STUDY [J].
DEVREUX, F ;
BOILOT, JP ;
CHAPUT, F ;
LECOMTE, A .
PHYSICAL REVIEW A, 1990, 41 (12) :6901-6909
[6]   SOL-GEL DERIVED TITANIUM CARBOXYLATE THIN-FILMS FOR OPTICAL-DETECTION OF ANALYTES [J].
DUNUWILA, DD ;
TORGERSON, BA ;
CHANG, CK ;
BERGLUND, KA .
ANALYTICAL CHEMISTRY, 1994, 66 (17) :2739-2744
[7]   Kinetic and equilibrium studies on mercury(II)-coproporphyrin-I. Metal ion exchange reaction with cobalt(II) and application to determination of trace mercury(II) [J].
Giovannetti, R ;
Bartocci, V .
TALANTA, 1998, 46 (05) :977-984
[8]   PREPARATION AND PROPERTIES OF SOL-GEL THIN-FILMS WITH PORPHINS [J].
INOUE, H ;
IWAMOTO, T ;
MAKISHIMA, A ;
IKEMOTO, M ;
HORIE, K .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 1992, 9 (05) :816-818
[9]   ADVANCED ALGORITHM FOR DETERMINING COMPONENT SPECTRA BASED ON PRINCIPAL COMPONENT ANALYSIS [J].
KAWATA, S ;
KOMEDA, H ;
SASAKI, K ;
MINAMI, S .
APPLIED SPECTROSCOPY, 1985, 39 (04) :610-614
[10]   Optical sensor for oxygen using a porphyrin-doped sol-gel glass [J].
Lee, SK ;
Okura, I .
ANALYST, 1997, 122 (01) :81-84