Electrochemical immunoassay of human chorionic gonadotrophin based on its immobilization in gold nanoparticles-chitosan membrane

被引:28
作者
Chen, J
Yan, F
Du, D
Wu, J
Ju, HX [1 ]
机构
[1] Nanjing Univ, Dept Chem, Educ Minist China, Key Lab Analyt Chem Life Sci, Nanjing 210093, Peoples R China
[2] Jiangsu Inst Canc Prevent & Cure, Nanjing 210009, Peoples R China
关键词
immunosensors; immunoassay; gold nanoparticles; chitosan; human chorionic gonadotrophin;
D O I
10.1002/elan.200503440
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A human chorionic gonadotrophin (hCG) doped gold nanoparticles-chitosan membrane was prepared for forming an immunoconjugate of horseradish peroxidase labeled hCG antibody and hCG on glassy carbon electrode. The nanoparticles provided a congenial environment of the adsorbed proteins. Thus, the immobilized HRP-labeled immunoconjugate showed good enzymatic activity for the oxidation of o-phenylenediamine by H2O2. With a competitive mechanism, an amperometric method for immunoassay of hCG up to 30 mIU mL(-1) with a relatively low detection limit of 0.26 mIU mL(-1) at 3 sigma was developed. The hCG immunosensor showed good precision, high sensitivity, acceptable stability and reproducibility.
引用
收藏
页码:670 / 676
页数:7
相关论文
共 38 条
[1]   Immobilization of peroxidase glycoprotein on gold electrodes modified with mixed epoxy-boronic acid monolayers [J].
Abad, JM ;
Vélez, M ;
Santamaría, C ;
Guisán, JM ;
Matheus, PR ;
Vázquez, L ;
Gazaryan, I ;
Gorton, L ;
Gibson, T ;
Fernández, VM .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2002, 124 (43) :12845-12853
[2]   ENZYME IMMUNOSENSOR .3. AMPEROMETRIC DETERMINATION OF HUMAN CHORIONIC-GONADOTROPIN BY MEMBRANE-BOUND ANTIBODY [J].
AIZAWA, M ;
MORIOKA, A ;
SUZUKI, S ;
NAGAMURA, Y .
ANALYTICAL BIOCHEMISTRY, 1979, 94 (01) :22-28
[3]  
Bagel O, 2000, ELECTROANAL, V12, P1447, DOI 10.1002/1521-4109(200012)12:18<1447::AID-ELAN1447>3.3.CO
[4]  
2-4
[5]   Electrochemical sensors [J].
Bakker, E .
ANALYTICAL CHEMISTRY, 2004, 76 (12) :3285-3298
[6]   Can affinity sensors be used to detect food contaminants? [J].
Bilitewski, U .
ANALYTICAL CHEMISTRY, 2000, 72 (21) :692A-701A
[7]   An indirect perfluorosulfonated ionomer-coated electrochemical immunosensor for the detection of the protein human chorionic gonadotrophin [J].
Chetcuti, AF ;
Wong, DKY ;
Stuart, MC .
ANALYTICAL CHEMISTRY, 1999, 71 (18) :4088-4094
[8]   Electrode coatings based on chitosan scaffolds [J].
Cruz, J ;
Kawasaki, M ;
Gorski, W .
ANALYTICAL CHEMISTRY, 2000, 72 (04) :680-686
[9]   Reagentless amperometric immunosensors based on direct electrochemistry of horseradish peroxidase for determination of carcinoma antigen-125 [J].
Dai, Z ;
Yan, F ;
Chen, J ;
Ju, HX .
ANALYTICAL CHEMISTRY, 2003, 75 (20) :5429-5434
[10]   An immunomagnetic electrochemical sensor based an a perfluorosulfonate-coated screen-printed electrode for the determination of 2,4-dichlorophenoxyacetic acid [J].
Dequaire, M ;
Degrand, C ;
Limoges, B .
ANALYTICAL CHEMISTRY, 1999, 71 (13) :2571-2577