Coacervative extraction of Ochratoxin A in wines prior to liquid chromatography/fluorescence determination

被引:36
作者
Garcia-Fonseca, Sergio [1 ]
Ballesteros-Gomez, Ana [1 ]
Rubio, Soledad [1 ]
Perez-Bendito, Dolores [1 ]
机构
[1] Edificio Anexo Marie Curie, Fac Ciencias, Dept Analyt Chem, Cordoba 14071, Spain
关键词
Ochratoxin A; wine; coacervate; reverse micelles; mycotoxins;
D O I
10.1016/j.aca.2007.11.002
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Coacervates made up of reverse micelles of decanoic acid were assessed as a new strategy for the simplification of wine sample treatment in the determination of Ochratoxin A (OTA). Simultaneous extraction/concentration of this contaminant was based on both hydrophobic and hydrogen bond OTA:coacervate interactions. Parameters affecting extraction efficiency and concentration factors were studied. Concentrations of decanoic acid and tetrahydrofuran (THF) were the most influential parameters, being 0.5% of acid and 5% of THF the selected ones. The procedure was very robust, so that the extractions were not influenced by the pH and the nature or concentration of matrix components. OTA recoveries from different types of wines (white, rose and red) ranged between 85 and 100% and the actual concentration factors varied from 105 to 125 for sample volumes of 15 mL. The detection limits for OTA, after liquid chromatography/fluorimetry (LC/FL) analysis of the coacervate (20 mu L), were 4.5 ng L-1 in white and rose wines and 15 ng L-1 in red wines, values which were far below the threshold limit established for OTA by EU directives (2.0 mu g L-1). No clean-up of the extracts was required for any of the samples analysed. The overall sample treatment took about 15-20 min and several samples could be simultaneously treated using conventional lab equipment. The precision of the method, expressed as relative standard deviation, was about 5%. The approach developed was successfully applied to the determination of OTA in different wine samples from the South of Spain. The concentrations found ranged between 0.015 and 0.091 mu g L-1. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:3 / 10
页数:8
相关论文
共 38 条
[1]  
[Anonymous], 2002, 327 SCOOP
[2]  
[Anonymous], 1993, Monographs on the Evaluation of Carcinogenic Risk to Humans, V56, P489
[3]  
*AOAC, 2002, 200101 AOAC
[4]   Determination of Ochratoxin A in wine at sub ng/mL levels by solid-phase microextraction coupled to liquid chromatography with fluorescence detection [J].
Aresta, Antonella ;
Vatinno, Rosa ;
Palmisano, Francesco ;
Zambonin, Carlo G. .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1115 (1-2) :196-201
[5]   Determination of bisphenols A and F and their diglycidyl ethers in wastewater and river water by coacervative extraction and liquid chromatography-fluorimetry [J].
Ballesteros-Gomez, Ana ;
Ruiz, Francisco-Javier ;
Rubio, Soledad ;
Perez-Bendito, Dolores .
ANALYTICA CHIMICA ACTA, 2007, 603 (01) :51-59
[6]   Determination of non-ionic polyethoxylated surfactants in sewage sludge by coacervative extraction and ion trap liquid chromatography-mass spectrometry [J].
Cantero, M ;
Rubio, S ;
Pérez-Bendito, D .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1046 (1-2) :147-153
[7]   Surfactant cloud point extraction and preconcentration of organic compounds prior to chromatography and capillary electrophoresis [J].
Carabias-Martínez, R ;
Rodríguez-Gonzalo, E ;
Moreno-Cordero, B ;
Pérez-Pavón, JL ;
García-Pinto, C ;
Laespada, EF .
JOURNAL OF CHROMATOGRAPHY A, 2000, 902 (01) :251-265
[8]   An acid-induced phase cloud point separation approach using anionic surfactants for the extraction and preconcentration of organic compounds [J].
Casero, I ;
Sicilia, D ;
Rubio, S ;
Pérez-Bendito, D .
ANALYTICAL CHEMISTRY, 1999, 71 (20) :4519-4526
[9]  
GANDER B, 2002, ENCY PHARM TECHNOLOG
[10]   Comparison between capillary electrophoresis and HPLC-FL for ochratoxin A quantification in wine [J].
González-Peñas, E ;
Leache, C ;
de Cerain, AL ;
Lizarraga, E .
FOOD CHEMISTRY, 2006, 97 (02) :349-354