Determination of Ochratoxin A in wine at sub ng/mL levels by solid-phase microextraction coupled to liquid chromatography with fluorescence detection

被引:68
作者
Aresta, Antonella [1 ]
Vatinno, Rosa [1 ]
Palmisano, Francesco [1 ]
Zambonin, Carlo G. [1 ]
机构
[1] Univ Bari, Dipartmento Chim, I-70126 Bari, Italy
关键词
mycotoxins; Ochratoxin-A; SPME; LC-FL; wine;
D O I
10.1016/j.chroma.2006.02.092
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Solid-phase microextraction (SPME), using a polydimethylsiloxane/divinylbenzene (PDMS/DVB) fiber, interfaced with liquid chromatography-fluorescence detection (LC-FD) has been applied to the determination of Ochratoxin A (OTA) in wine samples. Compared to the most widely adopted extraction/clean-up procedure based on immunoaffinity columns (IAC), the solventless extraction is simpler and cost-effective, requiring the simple immersion of the fiber in diluted wine samples. Furthermore, a fast LC separation is achieved under isocratic conditions. The linear range investigated in wine was 0.25-8 ng/mL; at fortification levels of 0.5 and 2 ng/mL, within-day intra-laboratory precision (repeatability) values, expressed as RSD%, were 5.9 and 5.1, respectively, whereas between days (n = 4) precision was 8.5 and 7.1%, respectively. The limit of detection (LOD) at a signal-to-noise (S/N) ratio of 3 was 0.07 ng/mL; the limit of quantification (LOQ) calculated at S/N = 10 was 0.22 ng/mL, well below the European regulatory level of 2ng/mL. The potential of the method has been demonstrated by the analysis of a number of different wine samples. (c) 2006 Elsevier B.V All rights reserved.
引用
收藏
页码:196 / 201
页数:6
相关论文
共 32 条
[1]  
[Anonymous], 2002, 327 SCOOP
[2]  
[Anonymous], 2001, WHO FOOD ADD SER, V47
[3]   Simultaneous determination of ochratoxin A and cyclopiazonic, mycophenolic, and tenuazonic acids in cornflakes by solid-phase microextraction coupled to high-performance liquid chromatography [J].
Aresta, A ;
Cioffi, N ;
Palmisano, F ;
Zambonin, CG .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2003, 51 (18) :5232-5237
[4]   AUTOMATION AND OPTIMIZATION OF SOLID-PHASE MICROEXTRACTION [J].
ARTHUR, CL ;
KILLAM, LM ;
BUCHHOLZ, KD ;
PAWLISZYN, J ;
BERG, JR .
ANALYTICAL CHEMISTRY, 1992, 64 (17) :1960-1966
[5]   Automated on-line solid-phase extraction-liquid chromatography-electrospray tandem mass spectrometry method for the determination of ochratoxin A in wine and beer [J].
Bacaloni, A ;
Cavaliere, C ;
Faberi, A ;
Pastorini, E ;
Samperi, R ;
Lagana, A .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2005, 53 (14) :5518-5525
[6]   SOLID-PHASE MICROEXTRACTION COUPLED TO HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
CHEN, J ;
PAWLISZYN, JB .
ANALYTICAL CHEMISTRY, 1995, 67 (15) :2530-2533
[7]   Rules for stating when a limiting value is exceeded [J].
Christensen, JM ;
Holst, E ;
Olsen, E ;
Wilrich, PT .
ACCREDITATION AND QUALITY ASSURANCE, 2002, 7 (01) :28-35
[8]   Reversed-phase liquid chromatographic method for the determination of ochratoxin A in wine [J].
Dall'Asta, C ;
Galaverna, G ;
Dossena, A ;
Marchelli, R .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1024 (1-2) :275-279
[9]   On the assessment of compliance with legal limits - Part 1: Signal and concentration domains [J].
Desimoni, E ;
Mannino, S ;
Brunetti, B .
ACCREDITATION AND QUALITY ASSURANCE, 2001, 6 (11) :452-458
[10]   Uncertainty of measurement and legislative limits [J].
Desimoni, E ;
Mannino, S .
ACCREDITATION AND QUALITY ASSURANCE, 1998, 3 (08) :335-337