Fast spin echo sequences with very long echo trains:: Design of variable refocusing flip angle schedules and generation of clinical T2 contrast

被引:285
作者
Busse, RF
Hariharan, H
Vu, A
Brittain, JH
机构
[1] GE Healthcare, Appl Sci Lab, Madison, WI USA
[2] GE Healthcare, Waukesha, WI USA
关键词
RARE; fast imaging; variable flip angle; T-2; contrast; echo stabilization;
D O I
10.1002/mrm.20863
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Reducing and continuously varying the flip angle of the refocusing RF pulses in a rapid acquisition with relaxation enhancement (RARE; fast/turbo spin echo) sequence is a useful means of addressing high RF power deposition and modulation transfer function (MTF) distortion due to relaxation. This work presents a streamlined technique to generate a sequence of refocusing flip angles on a per-prescription basis that produces relatively high SNR and limits blurring in a wide range of materials encountered in vivo. Since the "effective TV (traditionally defined as the time at which the center of k-space is sampled) no longer corresponds to the expected amount of spin-echo T-2 contrast due to the mixing of stimulated and spin echoes, a "contrast-equivalent" TE is defined and experimentally demonstrated that allows annotation of a more accurate effective TE that matches the contrast produced by 180 degrees refocusing. Furthermore, contrast is shown to be manipulable by the addition of magnetization preparation pulse sequence segments, such as T-2-prep, to produce clinically desirable contrast for routine head and body imaging.
引用
收藏
页码:1030 / 1037
页数:8
相关论文
共 14 条
[11]  
LEROUX P, 1993, MAGNET RESON MED, V30, P183, DOI 10.1002/mrm.1910300206
[12]  
Mugler JP., 2000, Proceedings of the 8th Annual Meeting of ISMRM, P687
[13]  
Mugler JP, 2003, P INT SOC MAG RESON, P203
[14]  
Schaffter T., 1994, P SMR 2 ANN M SAN FR, P27