AFM fishing nanotechnology is the way to reverse the Avogadro number in proteomics

被引:61
作者
Archakov, Alexander Ivanovich [1 ]
Ivanov, Yurii Dmitrievich [1 ]
Lisitsa, Andrey Valerevich [1 ]
Zgoda, Victor Gavrilovich [1 ]
机构
[1] Russian Acad Med Sci, Inst Biomed Chem, Moscow 119121, Russia
关键词
atomic-force microscopy; biospecific fishing; molecular detectors; nanobiotechnology;
D O I
10.1002/pmic.200600467
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Future development of proteomics may be hindered by limitations in the concentration sensitivity of widespread technological approaches. The concentration sensitivity limit (CSL) of currently used approaches, like 2-DE/LC separation coupled with MS detection, etc., varies from 10(-9) to 10(-12) M. Therefore, proteomic technologies enable detection of up to 20% of the protein species present in the plasma. New technologies, like atomic force microscopy (AFM molecular detector), enable the counting of single molecules, whereas biospecific fishing can be used to capture these molecules from the biomaterial. At the same time, fishing also has thermodynamic limitations due to the reversibility of the binding. In cases where the fishing becomes irreversible, its combination with an AFM detector enables the registration of single protein molecules, and that opens up a way to lower the CSL down to the reverse Avogadro number.
引用
收藏
页码:4 / 9
页数:6
相关论文
共 31 条
[1]   Mass spectrometry-based proteomics [J].
Aebersold, R ;
Mann, M .
NATURE, 2003, 422 (6928) :198-207
[2]  
ALBRECHTBUEHLER G, 1990, INT REV CYTOL, V120, P191
[3]   The human plasma proteome - History, character, and diagnostic prospects [J].
Anderson, NL ;
Anderson, NG .
MOLECULAR & CELLULAR PROTEOMICS, 2002, 1 (11) :845-867
[4]   Comparison of different depletion strategies for improved resolution in proteomic analysis of human serum samples [J].
Björhall, K ;
Miliotis, T ;
Davidsson, P .
PROTEOMICS, 2005, 5 (01) :307-317
[5]   Protein arrays: The current state-of-the-art [J].
Cutler, P .
PROTEOMICS, 2003, 3 (01) :3-18
[6]   Detecting single stranded DNA with a solid state nanopore [J].
Fologea, D ;
Gershow, M ;
Ledden, B ;
McNabb, DS ;
Golovchenko, JA ;
Li, JL .
NANO LETTERS, 2005, 5 (10) :1905-1909
[7]   Protein detection using proximity-dependent DNA ligation assays [J].
Fredriksson, S ;
Gullberg, M ;
Jarvius, J ;
Olsson, C ;
Pietras, K ;
Gústafsdóttir, SM ;
Östman, A ;
Landegren, U .
NATURE BIOTECHNOLOGY, 2002, 20 (05) :473-477
[8]  
Garcia-Parajo MF, 1999, CYTOMETRY, V36, P239, DOI 10.1002/(SICI)1097-0320(19990701)36:3<239::AID-CYTO14>3.0.CO
[9]  
2-Y
[10]   Nanotechnologies in proteomics [J].
Ivanov, YD ;
Govorun, VM ;
Bykov, VA ;
Archakov, AI .
PROTEOMICS, 2006, 6 (05) :1399-1414